Related Experiment Video
Updated: Jun 22, 2026

Façade-Level Monitoring of CO2 Variability under Urban Heat Island Conditions using Low-Cost Sensor Data Loggers
Published on: December 12, 2025
Temporal evolution of the main processes that control indoor pollution in an office microenvironment: a case study
Christos H Halios1, Costas G Helmis
1Department of Environmental Physics and Meteorology, Faculty of Physics, University of Athens, Building Phys-5, University Campus, 157 84, Athens, Greece. c_halios@phys.uoa.gr
Abstract:
The aim of this study is to examine the relative contribution of the outdoor concentration, the ventilation rate, the geometric characteristics of the indoor environment (i.e., extent of indoor surfaces and indoor volume), the deposition, and chemical reactions to the indoor air quality of the office microenvironment. For this case study, the NO, NO2, and O3 concentrations indoors and outdoors and TVOCs and CO2 concentrations indoors were measured in an office microenvironment in Athens, Greece, that was ventilated both naturally and mechanically. The calculated ventilation and loss rates and the measured outdoor concentrations of NO, NO2, and O3 were set as input to Multi-chamber Indoor Air Quality Model in order to study the temporal variation of the indoor NO, NO2, and O3 concentrations. Results showed that when the ventilation rate and outdoor concentration are high, the relative contribution of the transport process contributes significantly, while the chemical process depends on the contemporary interplay between the indoor O3, NO, and NO2 concentrations and lighting levels. The significance of each process was further examined by performing sensitivity tests, and it was found that the most important parameters were the deposition velocities, the UV infiltration rates (which determines the indoor chemical reaction rates), the ventilation rates, and the filtration (when a mechanical ventilation system is used). The effect of the hydrocarbon chemistry was not significant.
More Related Videos
09:46Production and Measurement of Organic Particulate Matter in the Harvard Environmental Chamber
Published on: November 18, 2018
09:33Visualizing Field Data Collection Procedures of Exposure and Biomarker Assessments for the Household Air Pollution Intervention Network Trial in India
Published on: December 23, 2022
Related Concept Videos
Microenvironments
Chemical Factors Affecting Respiration Centers
CO2 has a potent influence on respiration and is strictly regulated. Under...
Environmental Applications of Microorganisms
Factors Affecting Pulmonary Ventilation
Alveolar Surface Tension
The alveolar fluid lines the luminal surface of the alveoli and exerts a force called surface tension. This force is caused by the polar water molecules in the liquid being more strongly attracted to each...
Other Factors Affecting Respiration Centers
However, the ability to hold one's breath voluntarily is not limitless. When the CO2 concentration in the blood reaches a critical level,...
Microbes and Climate Change