Related Experiment Video
Updated: Jun 22, 2026

11:41
Evaluation of an Exclusive Spur Dike U-Turn Design with Radar-Collected Data and Simulation
Published on: February 1, 2020
Abstract:
In the Notch pathway, the transmembrane ligand Delta is internalized and then re-established on the surface of signal-sending cells to allow the productive binding and activation of the Notch receptor on neighbouring cells. Arp2/3-dependent actin polymerization directs Delta trafficking through this circuit.
Related Concept Videos
Transport Number
The transport number is the fraction of the total current carried by an ion in an electrolyte solution. It is defined as the ratio of the current carried by a specific ion to the total current flowing through the solution. The transport number, t, is central to understanding ionic mobility, which describes how fast an ion moves under the influence of an electric field. This link connects the physical behavior of ions in solution to the chemical processes that occur during electrochemical...
IP3/DAG Signaling Pathway
Membrane lipids such as phosphatidylinositol (PI) are precursors for several membrane-bound and soluble second messengers. Specific kinases phosphorylate PI and produce phosphorylated inositol phospholipids. One such inositol phospholipids are the phosphatidylinositol-4,5 bisphosphate [PI(4,5)P2], present in the inner half of the lipid bilayer. Upon ligand binding, GPCR stimulates Gq proteins to turn on phospholipase Cꞵ. Activated phospholipase Cꞵ cleaves PI(4,5)P2 and produces two-second...
Transformers with Off-Nominal Turns Ratios
In scenarios involving parallel transformers with disparate ratings, developing per-unit models requires accommodating off-nominal turns ratios. This situation arises when the selected base voltages are not proportional to the transformer’s voltage ratings. Consider a transformer where the rated voltages are related by the term a. If the chosen voltage bases satisfy a relationship involving term b, term c is defined as the ratio of these bases. This ratio is then substituted into the rated...
Directional Relays
Directional relays, essential for managing unidirectional fault currents, enhance the safety and efficiency of power systems. On power lines equipped with directional relays, faults downstream (to the right) of the current transformer typically cause the fault current to lag the bus voltage by approximately 90 degrees, known as the forward direction. In contrast, upstream (left-side) faults may result in the fault current leading the bus voltage by nearly 90 degrees, termed the reverse...
Social Traps
Social traps are negative situations where people get caught in a direction or relationship that later proves to be unpleasant, with no easy way to back out of or avoid. The concept was orignally introduced by John Platt who applied psychology to Garrett Hardin's "Tragedy of the Commons", where in New England herd owners could let their cattle graze in the common ground. This situation seems like a good idea, but an individual could have an advantage. If they owned more cows, the larger...
Derivatives of Inverse Trigonometric Functions
A ship tracking an approaching aircraft relies on geometric measurements to find out the aircraft’s position relative to the observer. By measuring the slant distance to the aircraft and the angle of elevation, the horizontal and vertical components of the distance can be obtained using trigonometric relationships. This geometric approach provides a basis for analyzing how the observed angle changes as the aircraft moves closer to the ship.To examine the mathematical behavior of the angle of...