Related Experiment Video
Updated: Jun 22, 2026

Liquid Chromatography Coupled to Refractive Index or Mass Spectrometric Detection for Metabolite Profiling in Lysate-based Cell-free Systems
Published on: September 23, 2021
Fast liquid chromatography separation and multiple-reaction monitoring mass spectrometric detection of
Loubna A Hammad1, Matthew Neely, Bob Bridge
1METACyt Biochemical Analysis Center, Department of Chemistry, Indiana University, Bloomington 47405, USA.
Abstract:
We describe here the fast LC-MS/MS separation of a mixture of neurotransmitters consisting of dopamine, epinephrine, norepinephrine, 3,4-dihydroxybenzylamine (DHBA), salsolinol, serotonin, and gamma-aminobutyric acid (GABA). The new UltiMate 3000 Rapid Separation system (RSLC) was successfully coupled to the 4000 QTRAP mass spectrometer operating in multiple-reaction monitoring (MRM) mode. The separation was attained using a 100 mm length, 2.2 microm particle size Acclaim column at a flow rate of 0.5 mL/min. The column back pressure was 350 bar, while the total run time including column re-equilibration was 5.2 min. The peak resolution was minimally affected by the fast separation. The RSLC-MRM separation was found to have a precision range based on peak area for 50 replicate runs of 2-5% CV for all analytes, and the reproducibility of the retention time for all analytes was found to range from 0-2% CV. The described method represents an almost seven times shorter analysis time of neurotransmitters using LC/MRM which is very useful in screening large quantities of biological samples for various neurotransmitters.
More Related Videos
13:35A Convenient Method for Extraction and Analysis with High-Pressure Liquid Chromatography of Catecholamine Neurotransmitters and Their Metabolites
Published on: March 1, 2018
10:17High-throughput and Comprehensive Drug Surveillance Using Multisegment Injection-Capillary Electrophoresis-Mass Spectrometry
Published on: April 23, 2019
Related Concept Videos
High-Performance Liquid Chromatography: Types of Detectors
Tandem Mass Spectrometry
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Peptide Identification Using Tandem Mass Spectrometry
This technique helps gather information regarding the protein from which the peptide was obtained and to study the peptides’ amino acid sequence. Identifying peptides from a complex mixture is an important component of the growing field of...
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall. The coating...
MALDI-TOF Mass Spectrometry