Related Experiment Video
Updated: Jun 21, 2026

Computed Tomography (CT) Guided Implantation of a Totally Implantable Venous Access Port (TIVAP) through Subclavian Vein
Published on: January 13, 2026
A new technique to remove a "stuck" totally implantable venous access catheter
Shu-Chien Huang1, Ming-Shian Tsai, Hong-Shiee Lai
1Department of Surgery, National Taiwan University Hospital and National Taiwan University College of Medicine,Taipei, Taiwan.
Abstract:
Removal of a totally implantable venous access device (port) is usually a simple procedure; however, if a catheter has been in place for a very long period, it may adhere firmly to the vessel wall. We report a new technique to facilitate removal of a stuck catheter. A 16-year-old girl was admitted for removal of her port, which had been inserted for chemotherapy 11 years earlier. After her disease was controlled, the catheter could not be pulled out during surgery. To remove the catheter, we inserted a guidewire to straighten the catheter and then applied a "push-in" force to detach the adherence from the central vein. The catheter was then removed successfully. We believe that this is a new and simple method for removing a "stuck" catheter.