Related Experiment Video
Updated: Jun 21, 2026

An Introduction to Processing, Fitting, and Interpreting Transient Absorption Data
Published on: February 16, 2024
Contrast agent response to chirp reversal: simulations, optical observations, and acoustical verification
Anthony Novell1, Sander van der Meer, Michel Versluis
1Inserm UMR 930, CNRS ERL 3106, Tours, France.
Abstract:
Active response of a microbubble is characterized by its resonance behavior where the microbubble might oscillate after the excitation waveform has been turned off. We investigate in this paper an excitation approach based on this resonance phenomenon using chirps. The technique, called chirp reversal, consists in transmitting a first excitation signal, the up-sweep chirp (UPF) of increasing frequency with time, and a second excitation signal, the down-sweep (DNF) that is a replica of the first signal, but time reversed with a sweep of decreasing frequency with time. Simulations using a modified Rayleigh-Plesset equation were carried out to determine bubble response to chirp reversal. In addition, optical observations and acoustical measurements were carried out to corroborate the theoretical findings. Results of simulations show differences between bubbles' oscillations in response to up-sweep and down-sweep chirps mainly for transmitted center frequencies above the bubble's resonance frequency. Bubbles that are at resonance or far away from resonance engender identical responses. From the optical data, the larger bubbles showed different dynamics when up-sweep or down-sweep chirps were transmitted. Smaller bubbles (< 2 microm diameter) appear to be less sensitive to frequency sweep at 1.7 MHz center frequency. However, driven at a higher center frequency, smaller bubbles tend to be more sensitive. These results were confirmed through the acoustical measurements. We concluded that simulations and experimental data show that significant differences might be observed between bubbles' responses to UPF and DNF chirps. We demonstrate in this study that, for an optimal use of chirp reversal, the transmit frequency should be higher than the resonance frequency of the contrast microbubbles.
More Related Videos
09:56Universal Hand-held Three-dimensional Optoacoustic Imaging Probe for Deep Tissue Human Angiography and Functional Preclinical Studies in Real Time
Published on: November 4, 2014
10:17Switchable Acoustic and Optical Resolution Photoacoustic Microscopy for In Vivo Small-animal Blood Vasculature Imaging
Published on: June 26, 2017
Related Concept Videos
Double Resonance Techniques: Overview
Spin decoupling is usually achieved by...
Doppler Effect - II