Related Experiment Video
Updated: Jun 21, 2026

Tracing de novo Lipids using Stable Isotope Labeling LC-TIMS-TOF MS/MS
Published on: August 23, 2024
Real-time trace detection of security-relevant compounds in complex sample matrices by thermal desorption-single
Elisabeth Schramm1, Jasper Hölzer, Michael Pütz
1Helmholtz Zentrum München, Institute of Ecological Chemistry, Ingolstädter Landstrasse 1, 85764, Neuherberg, Germany.
Abstract:
For the detection of security-relevant substances at low concentrations in complex matrices, coupling of thermal desorption-single photon ionization-ion trap mass spectrometry (TD-SPI-ITMS) was successfully tested. The main advantage of taking solid samples with a wipe pad followed by thermal desorption is the low detection limit by enhanced vapor pressure. Single photon ionization is a soft ionization technique which reduces the target ion fragmentation and shields bulk components with high ionization energies (IE) like nitrogen yielding to clearly arranged mass spectra with significant high mass peaks. To obtain low false-positive and false-negative rates, especially necessary for security-relevant substances, the ion trap mass spectrometer allows identification of signals with MS/MS studies. In this concept, the soft ionization technique fits well with the MS/MS studies, as peaks with high masses are generated yielding significant MS/MS fragments. For the ionization, photon energies between about 8 eV (155 nm) and 12 eV (103 nm) were generated with electron-beam-pumped rare gas excimer lamps (EBEL). Depending on the rare gas used, light with different photon energy is generated, adapted to the substances of interest. So, even most narcotics, having relatively low IEs, can be ionized with 8.4 eV photons without massive fragmentation. For most explosives, photons with higher energy must be used as their IEs are higher. In this work, a mobile setup with a commercial ion trap mass spectrometer has been developed and tested. Even a first real-scenario measurement campaign was accomplished successfully proving the field-suitability of the system.
More Related Videos
08:43PTR-ToF-MS Coupled with an Automated Sampling System and Tailored Data Analysis for Food Studies: Bioprocess Monitoring, Screening and Nose-space Analysis
Published on: May 11, 2017
09:38Dithranol as a Matrix for Matrix Assisted Laser Desorption/Ionization Imaging on a Fourier Transform Ion Cyclotron Resonance Mass Spectrometer
Published on: November 26, 2013
Related Concept Videos
Tandem Mass Spectrometry
MALDI-TOF Mass Spectrometry
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Peptide Identification Using Tandem Mass Spectrometry
This technique helps gather information regarding the protein from which the peptide was obtained and to study the peptides’ amino acid sequence. Identifying peptides from a complex mixture is an important component of the growing field of...
High-Performance Liquid Chromatography: Types of Detectors
Matrix-Assisted Laser Desorption Ionization (MALDI)