Fibrin sealant in inguinal hernioplasty: an observational multicentre study in 1,201 patients
1Department of Visceral Surgery and Transplantation, Dupuytren University Hospital, Limoges, France.
Purpose:
A prospective, multicentre, observational study was undertaken to assess Tisseel fibrin sealant for atraumatic mesh fixation in inguinal hernia repair throughout France.
Methods:
Surgeons recorded data on patients undergoing tension-free inguinal hernioplasty with mesh fixation with Tisseel, regardless of the hernioplasty technique used. Assessments were made at 2 days and 1 month after surgery. Data on local complications, operation times and ease of product use were collected.
Results:
In total, 1,201 patients were recruited (90% men, mean age 57 years), among which 526 procedures were performed using open techniques and 675 using laparoscopic repairs. Local complications occurred in 4.7% of patients: 3.0% haematoma, 1.4% seroma, 0.3% recurrence. The mean visual analogue scale (VAS)-rated pain scores were 3.2 pre-operatively, 2.3 immediately after surgery and 1.8 at 1 month. Surgeons rated the product as very easy to use.
Conclusions:
Tisseel fibrin sealant appears to be a well-tolerated and easy-to-use alternative to traditional, tissue-penetrating devices for mesh fixation in hernia repair techniques.