Related Experiment Video
Updated: Aug 9, 2026

The WATCHMAN Left Atrial Appendage Closure Device for Atrial Fibrillation
Published on: February 28, 2012
Low-intensity anticoagulation in mechanical cardiac prosthetic valves
D B Wilson1, M I Dunn, K Hassanein
1Department of Internal Medicine, University of Kansas Medical Center, Kansas City.
Abstract:
Retrospectively, we reviewed the charts of 101 patients at the University of Kansas Medical Center who received low-intensity anticoagulation for mechanical prosthetic valves implanted over a 17-yr period. The mean duration of follow-up was 4.6 yr, and the total duration of follow-up was 466.5 patient-yr. The patients' records were evaluated for evidence of hemorrhagic or thromboembolic complications. A prothrombin time ratio of 1.3 to 1.5 times control was considered to be low-intensity anticoagulation. There were three thromboembolic events or 2.9/100 patient-yr of follow-up at a prothrombin time ratio of less than 1.3, four thromboembolic events or 2.5/100 patient-yr of follow-up at 1.3 to 1.5 times control, four thromboembolic events or 2.2/100 patient-yr of follow-up at 1.6 to 2.0 times control, and no thromboembolic events at prothrombin time ratios greater than 2.0 times control. Hemorrhagic events occurred in three patients at a prothrombin time ratio of less than 1.3 times control or 2.8/100 patient-yr of follow-up, in six patients at 1.3 to 1.5 times control or 3.8/100 patient-yr of follow-up, in ten patients at 1.6 to 2.0 times control or 5.5/100 patient-yr of followup, and in two patients at 2.1 to 2.5 times control or 12.2/100 patient-yr of follow-up. The rate of hemorrhagic events at 2.5 times control was 470/100 patient-yr follow-up. While not providing definitive proof, we believe that our retrospective study provides supportive evidence for the use of low-intensity anticoagulation in patients with mechanical cardiac prostheses.
Related Concept Videos
Anticoagulant Drugs: Low-Molecular-Weight Heparins
Heart Valves
The AV valves prevent the backflow of blood from the ventricles to the atria during ventricular contraction. These valves function with the assistance of the chordae tendineae and papillary muscles. When the ventricles are relaxed, the chordae tendineae are slack, allowing blood to flow from the atria into the...
Mitral Regurgitation III: Medical Management
Mitral Stenosis III: Medical Management
Aortic Regurgitation III: Medical Management
Venous Thrombosis III: Interprofessional Care