Abstract:
The objective of this study was to investigate the possibility of using low-amperage electrical treatment (LAET) as a selective bacteriocide. Mixtures containing Escherichia coli, Staphylococcus aureus, and Vibrio parahaemolyticus were treated with different electric current intensities and for different times. The results showed that at 263 mA, treating bacteria for 100 ms eliminated all V. parahaemolyticus colonies. Although LAET reduced the populations of the three microorganisms, V. parahaemolyticus was more injured by LAET than S. aureus and E. coli when treated at the same processing conditions.
Related Concept Videos
Methods of Sterilization II: Chemical Methods
Using chemical sterilization rather than heat to clean out equipment is recommended. It eradicates and removes all bacteria,...
Methods of Sterilization I: Physical Methods
Steam sterilization uses non-toxic, low-cost moist heat in the form of saturated steam under pressure, which is fast, microbicidal, and sporicidal, and quickly warms and penetrates fabrics. Autoclaves, or steam sterilizers, expose each item to direct steam contact for a predetermined time at the necessary...