Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Gas Chromatography: Sample Injection Systems01:08

Gas Chromatography: Sample Injection Systems

In gas chromatography, the sample is introduced as a vapor plug into the carrier gas stream for high efficiency and resolution. A microsyringe injects the sample solution into a heated sample port, vaporizing it and mixing it with the carrier gas. This process is important to ensure the sample is properly prepared for analysis. Thermally sensitive samples can be injected directly into the column and volatilized by slowly increasing the column temperature.
Two primary injection methods are used...
Gas Chromatography–Mass Spectrometry (GC–MS)01:14

Gas Chromatography–Mass Spectrometry (GC–MS)

Gas chromatography–mass spectrometry (GC–MS) is the combination of analytical techniques of gas chromatography and mass spectrometry in a single instrument for analyzing a mixture of compounds. The gas chromatograph separates the compounds in the mixture, and the mass spectrometer analyzes each compound separately to determine the molecular masses and molecular structures.
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall. The coating...
Gas Chromatography: Types of Detectors-II01:19

Gas Chromatography: Types of Detectors-II

In gas chromatography, different detectors are employed to meet specific analytical needs. These detectors are often categorized based on their detection mechanisms and the types of compounds they are best suited to analyze. Thermal Conductivity Detectors (TCD), Flame Ionization Detectors (FID), and Electron Capture Detectors (ECD) represent common categories, each with unique operating principles and applications. However, beyond these, several other detectors are designed for more specialized...
High-Performance Liquid Chromatography: Elution Process01:05

High-Performance Liquid Chromatography: Elution Process

In High-Performance Liquid Chromatography (HPLC), the elution process is critical to the separation of analytes and the quality of chromatographic results. Elution describes how compounds move through the column and separate based on their interactions with the mobile and stationary phases. This process determines the resolution, peak shape, and retention times in the chromatogram, which are essential for identifying and quantifying components in complex mixtures. Understanding the elution...
Gas Chromatography: Introduction01:13

Gas Chromatography: Introduction

Gas chromatography (GC) is a technique for separating and analyzing volatile compounds in a sample. Its primary purpose is to identify and quantify components in complex mixtures, making it essential in fields such as environmental analysis, pharmaceuticals, and petrochemicals. GC is also called vapor-phase chromatography (VPC) or gas-liquid partition chromatography (GLPC).
In GC,  a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a column.
Mass Spectrometry: Complex Analysis01:21

Mass Spectrometry: Complex Analysis

Mass spectrometry is an important technique for the identification of pure compounds. However, it has some limitations for the analysis of complex mixtures, often due to excessive fragmentation making the spectrum too complicated to decipher. Mass spectrometry can be combined with suitable separation methods in sequence, forming hyphenated methods, which are useful in the analysis of complex mixtures.
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Optimisation of Electrokinetic Extraction System: Colourimetric Determination of Copper (II) in Sand Using Polymer Inclusion Membrane.

Electrophoresis·2026
Same author

Development of a sequential injection analysis method for the automatic simultaneous determination of sulfite and sulfate in water samples.

Talanta·2026
Same author

Iodine-starch reaction renewed: determination of iodate in table salts <i>via</i> the lab-in-syringe technique.

Analytical methods : advancing methods and applications·2026
Same author

3D printed liquid membrane transport system.

HardwareX·2026
Same author

Development of two flow analysis methods for the determination of tiopronin in pharmaceuticals.

Talanta·2026
Same author

Effect of Glass Fibers on the Mechanical and Transport Properties of Polymer Inclusion Membranes Composed of Aliquat 336 and PVDF-HFP.

Membranes·2026

Related Experiment Video

Updated: Jun 21, 2026

Quantitative Detection of Trace Explosive Vapors by Programmed Temperature Desorption Gas Chromatography-Electron Capture Detector
07:57

Quantitative Detection of Trace Explosive Vapors by Programmed Temperature Desorption Gas Chromatography-Electron Capture Detector

Published on: July 25, 2014

Highly sensitive gas-diffusion sequential injection analysis based on flow manipulation.

Spas D Kolev1, Paula R L V Fernandes, Dalibor Satinsky

  • 1School of Chemistry, The University of Melbourne, Parkville, Victoria 3010, Australia. s.kolev@unimelb.edu.au

Talanta
|July 21, 2009
PubMed
Summary
This summary is machine-generated.

Sequential injection analysis (SIA) significantly enhances gas-diffusion separation efficiency for ammonia and amines. This method offers over tenfold sensitivity improvement compared to flow injection analysis (FIA), especially for larger molecules.

More Related Videos

Measuring Dissolved Methane in Aquatic Ecosystems Using An Optical Spectroscopy Gas Analyzer
05:00

Measuring Dissolved Methane in Aquatic Ecosystems Using An Optical Spectroscopy Gas Analyzer

Published on: July 26, 2024

Real-time Breath Analysis by Using Secondary Nanoelectrospray Ionization Coupled to High Resolution Mass Spectrometry
08:23

Real-time Breath Analysis by Using Secondary Nanoelectrospray Ionization Coupled to High Resolution Mass Spectrometry

Published on: March 9, 2018

Related Experiment Videos

Last Updated: Jun 21, 2026

Quantitative Detection of Trace Explosive Vapors by Programmed Temperature Desorption Gas Chromatography-Electron Capture Detector
07:57

Quantitative Detection of Trace Explosive Vapors by Programmed Temperature Desorption Gas Chromatography-Electron Capture Detector

Published on: July 25, 2014

Measuring Dissolved Methane in Aquatic Ecosystems Using An Optical Spectroscopy Gas Analyzer
05:00

Measuring Dissolved Methane in Aquatic Ecosystems Using An Optical Spectroscopy Gas Analyzer

Published on: July 26, 2024

Real-time Breath Analysis by Using Secondary Nanoelectrospray Ionization Coupled to High Resolution Mass Spectrometry
08:23

Real-time Breath Analysis by Using Secondary Nanoelectrospray Ionization Coupled to High Resolution Mass Spectrometry

Published on: March 9, 2018

Area of Science:

  • Analytical Chemistry
  • Separation Science

Background:

  • Traditional gas-diffusion separation in flow injection analysis (FIA) faces limitations in efficiency and sensitivity.
  • Optimizing analyte transport and separation is crucial for sensitive chemical analysis.

Purpose of the Study:

  • To explore sequential injection analysis (SIA) for enhanced gas-diffusion separation.
  • To investigate various flow manipulation techniques within SIA to improve separation efficiency.
  • To quantify sensitivity improvements for model analytes compared to FIA.

Main Methods:

  • Utilized sequential injection analysis (SIA) with eleven distinct flow manipulation strategies.
  • Employed continuous flow, stop-flow, oscillating flow, and air-bubble injections.
  • Tested ammonia, ethylamine, diethylamine, and triethylamine as model analytes.
  • Compared results against traditional gas-diffusion flow injection analysis (FIA).

Main Results:

  • Achieved sensitivity improvements exceeding one order of magnitude over traditional FIA.
  • Observed a direct correlation between analyte molecular size and sensitivity enhancement.
  • Demonstrated the effectiveness of SIA's flow control for gas-diffusion processes.

Conclusions:

  • Sequential injection analysis (SIA) offers a powerful platform for optimizing gas-diffusion separations.
  • SIA provides substantial sensitivity gains for volatile amine analysis.
  • The molecular size-dependent improvement highlights SIA's potential for selective separation.