Determination of inorganic pharmaceutical counterions using hydrophilic interaction chromatography coupled with a
1Bristol-Myers Squibb, Research and Development, 1 Squibb Drive, New Brunswick, NJ 08901, USA. zongyun.huang@bms.com
Abstract:
A simple generic approach was investigated for the determination of inorganic pharmaceutical counterions in drug substances using conventional high performance liquid chromatographic (HPLC) instruments. An intuitive approach combined Corona charged aerosol detection (CAD) with a polymer-based zwitterionic stationary phase in the hydrophilic interaction chromatography (HILIC) mode. Two generic methods based on this HILIC/CAD technique were developed to quantitate counterions such as Cl-, Br-, SO(4)(2-), K+, Ca2+ and Mg2+ in different pharmaceutical compounds. The development and capability of this HILIC/CAD technique analysis were examined. HILIC/CAD was compared to ion chromatography (IC), the most commonly used methodology for pharmaceutical counterion analysis. HILIC/CAD was found to have significant advantages in terms of: (1) being able to quantitate both anions and cations simultaneously without a need to change column/eluent or detection mode; (2) imposing much less restriction on the allowable organic percentage of the eluents than IC, and therefore being more appropriate for analysis of counterions of poorly water-soluble drugs; (3) requiring minimal training of the operating analysts. The precision and accuracy of counterion analysis using HILIC/CAD was not compromised. A typical precision of <2.0% was observed for all tested inorganic counterions; the determinations were within 2.0% relative to the theoretical counterion amount in the drug substance. Additionally, better accuracy was shown for Cl- in several drug substances as compared to IC. The main drawback of HILIC/CAD is its unsuitability for many of the current silica-based HILIC columns, because slight dissolution of silica leads to high baseline noise in the CAD detector. As a result of the universal detection characteristics of Corona CAD and the unique separation capabilities of a zwitterionic stationary phase, an intuitive and robust HPLC method was developed for the generic determination of various counterions in different drug substances. HILIC/CAD technique is a useful alternative methodology, particularly for determination of counterions in low-solubility drugs.
More Related Videos
08:21Determination of Inorganic Arsenic in a Wide Range of Food Matrices using Hydride Generation - Atomic Absorption Spectrometry.
Published on: September 1, 2017
08:56Detection of Regulated Ergot Alkaloids in Food Matrices by Liquid Chromatography-Trapped Ion Mobility Spectrometry-Time-of-Flight Mass Spectrometry
Published on: November 22, 2024
Related Concept Videos
Ion-Exchange Chromatography
Gravimetry: Inorganic And Organic Precipitating Agents
High-Performance Liquid Chromatography: Types of Detectors
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
Qualitative Analysis
For instance, group IV...
Precipitation of Ions
The equation that describes the equilibrium between solid calcium carbonate and its solvated ions is: