Related Experiment Video
Updated: Jun 21, 2026

Magnetic Resonance Imaging Quantification of Pulmonary Perfusion using Calibrated Arterial Spin Labeling
Published on: May 30, 2011
[Evaluation of circulatory state using pulse oximeter: 2. PI (perfusion index) x PVI (pleth variability index)]
Toru Kaneda1, Toshiyasu Suzuki
1Department of Anesthesiology, Tokai University School of Medicine, Isehara 259-1193.
Abstract:
Pulse oximeter expressed by SpO2 is used for monitoring respiratory state during operation and in ICU. Perfusion index (PI) and pleth variability index (PVI) as new indexes are calculated from pulse oximeter (Masimo SET Radical-7, Masimo Corp., USA, 1998) waveforms. And these indices were used as parameters to evaluate the circulatory state. For PI calculation, the pulsatile infrared signal is indexed against the nonpulsatile infrared signal and expressed as a percentage. It might thus be of future value in assessment of perioperative changes in peripheral perfusion. PVI is a measure of a dynamic change in PI that occurs during complete respiratory cycle. It might be thought that PVI, an index automatically derived from the pulse oximeter waveform analysis, had potentially clinical applications for noninvasive hypovolemia detection and fluid responsiveness monitoring.
More Related Videos
07:51Standardized Hemorrhagic Shock Induction Guided by Cerebral Oximetry and Extended Hemodynamic Monitoring in Pigs
Published on: May 21, 2019
14:28Non-Invasive Monitoring of Microvascular Oxygenation and Reactive Hyperemia using Hybrid, Near-Infrared Diffuse Optical Spectroscopy for Critical Care
Published on: May 10, 2024
Related Concept Videos
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Guidelines For Measuring Vital Signs
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this principle...
Cardiovascular System Abnormal Findings I: Inspection and Palpation
Abnormal findings observed during an inspection
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above the...
Pulse
Pulse Rate and its Significance
Pulse rate, often measured in beats per minute (bpm), reflects the heart rate (HR), which is influenced by numerous factors such as stress, physical activity, and hormonal changes. A normal resting adult pulse rate falls between...