Related Experiment Video
Updated: Jun 21, 2026

Transmesenteric Laparoscopic Pyeloplasty in Trendelenburg Position for Horseshoe Kidney with Hydronephrosis
Published on: July 8, 2025
Endoscopic bridge operating-guide device applied for intracorporeal antegrade ureteric stenting during laparoscopic
Amine Derouiche1, Rabii El Atat, Mohamed Riadh Ben Slama
1Department of Urology, Charles Nicolle Hospital, Tunis, Tunisia.
Aim:
To describe our novel technique of laparoscopic pyeloplasty with an antegrade placement of a ureteral stent with a bridge operating-guide device (BOGD).
Methods:
After completing the posterior suture line of the dismembered pyeloplasty, a guidewire is inserted through the BOGD and grasped within the renal pelvis. Then, the BOGD is removed and the ureteral stent advanced until it is positioned in the renal pelvis, and the lower end of the stent lies in the bladder. The anastomosis is completed. Fifteen patients underwent the laparoscopic placement of ureteral stents with this technique.
Results:
With this method, the ureteral stent insertion is very convenient and time saving (the mean time for inserting a stent was 5 minutes). The stents were successfully inserted in all patients.
Conclusions:
This technique is reliable and effective in laparoscopic ureteral operations. It uses an endoscopic urological equipment, and costs are reduced.