[Reliability of cardiac output by thermodilution. Effect of marker temperature]
R M Tarradell Zamora1, J Alvarez Escudero, J Correa López
1Servicio de Anestesiología, Hospital de la Santa Creu i Sant Pau, Facultad de Medicina, Universidad Autónoma, Barcelona.
Abstract:
Classically, the cardiac output is measured by the thermodilution method, employing a standard volume of 5% D/W at 4 degrees C. Recently, however, a room-temperature (17-24 degrees C) measurements have been used, in such a way that a lower gradient between the injectate and the patient temperature is established. This lact could question the sensitivity and reliability of the technique evaluated. We have studied 20 patients undergoing different operations, in whom the cardiac output was measured by injecting a standard volume of 5 ml 5% D/W at room-temperature or at 5 degrees C, randomly assigned, in order to evaluate any difference between the two techniques. Over a total of 100 cardiac output determinations taken in normothermic conditions (19-24 degrees C) the mean was 4.24 +/- 1.13 l/min (means +/- SD). In hypothermic conditions the cardiac output was 4.28 +/- 1.14 l/min (means +/- SD). Results showed no statistical difference between both methods.
Related Concept Videos
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Cardiac Output and Stroke Volume
In an average resting adult male, the typical cardiac output averages...
Cardiac Output I:Effect of Heart Rate on Cardiac Output
Cardiac output (CO) refers to the total amount of blood ejected by one of the ventricles in liters per minute (L/min). In a resting adult, CO ranges from 5 to 6 L/min, adjusting according to the body's metabolic requirements.
Effect of Heart Rate on Cardiac Output
Cardiac output adapts to metabolic demands during stress, physical activity, or illness. The autonomic nervous system regulates heart rate via the sinoatrial node. The parasympathetic nervous system decreases heart rate...
Cardiac Output II: Effect of Stroke Volume on Cardiac Output
Preload
Preload refers to the initial elongation of the cardiac myocytes before contraction and is related to the volume of blood filling the heart at the end of diastole, or end-diastolic volume. The...
Blood Studies for Cardiovascular System I: Cardiac Biomarkers
The essential diagnostic tools for detecting myocardial necrosis and monitoring individuals suspected of having acute coronary syndrome (ACS) include:
Troponins
Troponins, particularly cardiac troponins I and T, are the most precise and sensitive markers of myocardial injury. They are detectable within 4-6 hours of myocardial injury and remain...