Related Experiment Video
Updated: Jun 21, 2026

A High-throughput Method for Measurement of Glomerular Filtration Rate in Conscious Mice
Published on: May 10, 2013
Comparison of GFR measurements assessed from single versus multiple samples
Nicholas J Bird1, Christina Peters, A Robert Michell
1Department of Nuclear Medicine, Addenbrooke's Hospital, Cambridge, UK.
Single-sample glomerular filtration rate (GFR) measurements are as reliable as multisample GFR. This study found single-sample GFR comparable to multisample GFR when using independent reference methods.
Area of Science:
- Nephrology
- Renal Physiology
- Diagnostic Testing
Background:
- Previous studies compared single-sample glomerular filtration rate (GFR) against multisample GFR, but not against an independent reference method.
- This study aimed to compare single and multisample GFR against a simultaneous, independent multisample GFR using a different indicator.
Purpose of the Study:
- To evaluate the reliability of single-sample GFR (ssGFR) compared to multisample GFR (msGFR).
- To compare ssGFR and msGFR using two different indicators, chromium-51 ((51)Cr)-EDTA and iohexol, against each other and an independent reference.
Main Methods:
- A diagnostic test study involving 95 studies in 60 patients and 20 healthy volunteers.
- GFR was measured using simultaneous (51)Cr-EDTA and iohexol injections, with blood samples collected over 4 hours.
- Single-sample GFR was calculated using the Jacobsson method at 3 and 4 hours, and compared with msGFR using Bland-Altman analysis.
Main Results:
- Limits of agreement for ssGFR at 3 and 4 hours were comparable to those for msGFR.
- Precision of ssGFR at 4 hours using (51)Cr-EDTA was superior to msGFR with the same indicator.
- ssGFR showed similar repeatability to msGFR in healthy participants and detected food-induced GFR changes more confidently.
Conclusions:
- Single-sample GFR is a reliable method for measuring GFR, comparable to multisample GFR.
- This reliability is particularly noted when GFR is above 60 mL/min.
- Further research is needed to interpret differences between markers without a definitive gold standard like inulin.
Related Concept Videos
Drug Dosing in Renal Diseases: Measurement of Glomerular Filtration Rate
Drug Dosing in Renal Diseases: Estimation of Glomerular Filtration Rate Based on Serum Creatinine Concentration
Renal Clearance
Renal clearance refers to the volume of plasma cleared of a specific substance, such as creatinine, per unit of time. To measure clearance, urine samples are collected over a 24-hour period during each bladder voiding, followed by a single blood sample at the...
Drug Dosing in Renal Diseases: Measurement of Serum Creatinine Concentration and Clearance
Renal Drug Clearance: Comparison Between Renal Excretion Methods
Renal clearance is often associated with the renal glomerular filtration rate (GFR), which represents the rate at which plasma is filtered through the glomeruli in the kidney. When drug reabsorption is minimal and there is no active secretion, renal clearance is closely related to the...
Determination of Renal Drug Clearance: Graphical and Midpoint Methods
The graphical method involves plotting the rate of drug excretion in urine against the plasma drug concentration. By analyzing the graph, the clearance can be calculated and obtained. Drugs rapidly excreted by the kidneys exhibit a...

