The effectiveness of radioguided parathyroidectomy in patients with negative technetium tc 99m-sestamibi scans
Herbert Chen1, Rebecca S Sippel, Sarah Schaefer
1Section of Endocrine Surgery, Department of Surgery, University of Wisconsin Medical School, H4/750 Clinical Science Center, Madison, WI 53792, USA. chen@surgery.wisc.edu
Background:
Many surgeons have shown that radio-guided resection of parathyroid glands can facilitate intraoperative localization in selected patients with primary hyperparathyroidism, especially in the reoperative setting. However, in patients with negative technetium Tc 99m-sestamibi (hereafter referred to as "sestamibi") scans, the usefulness of the gamma probe is unclear. Thus, we were interested in determining the role of radio-guided techniques in patients with primary hyperparathyroidism and negative or nonlocalizing sestamibi scans.
Design:
Retrospective analysis of a prospective parathyroid database.
Setting:
Academic medical center.
Patients:
Seven hundred sixty-nine patients with primary hyperparathyroidism who had a sestamibi scan and underwent surgical invention by a single surgeon. All patients had radioguided parathyroidectomy using a handheld gamma probe.
Main Outcome Measures:
Radioactive counts, eucalcemia rate, and complications were compared between patients with positive and patients with negative sestamibi scans.
Results:
All enlarged parathyroid glands were localized with the gamma probe in patients with a negative or with a positive sestamibi scan with similar sensitivities. This occurred despite the fact that smaller parathryoid glands were present, on average, in patients with negative sestamibi scans (428 mg vs 828 mg, P = .001). Equivalent high postoperative eucalcemia rates (>98%) and low complication rates (0.5%) were achieved with radioguided techniques in both patient populations.
Conclusions:
Radioguided techniques are equally effective in patients with negative (nonlocalizing) sestamibi scans undergoing parathyroidectomy for primary hyperparathyroidism. Moreover, use of the gamma probe led to the detection of all parathyroid glands, including ectopically located ones. These data suggest that the gamma probe has an important role for localization of parathyroid glands in patients with negative preoperative sestamibi scans.
Related Concept Videos
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Imaging Studies III: Computed Tomography
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...