Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Chemical Shift: Internal References and Solvent Effects01:17

Chemical Shift: Internal References and Solvent Effects

In an NMR sample, precise measurement of the absolute absorption frequencies of nuclei is difficult. A standard internal reference compound is added, and the frequency difference between the reference signal and sample signals is measured.
The internal reference compound generally used in NMR spectroscopy is tetramethylsilane (TMS). TMS is preferred because it is chemically inert, soluble in NMR solvents, and easily removable. Also, the highly shielded methyl protons in TMS yield an intense...
Guidelines For Measuring Vital Signs01:19

Guidelines For Measuring Vital Signs

Following these guidelines can help nurses accurately measure vital signs, assess changes in patient conditions, and provide timely treatment when necessary. Adhering closely to the guidelines ensures the accuracy and reliability of the results.
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.
Bioequivalence studies: Biowaivers01:13

Bioequivalence studies: Biowaivers

In certain scenarios, in vitro dissolution tests can replace in vivo bioequivalence studies. This is particularly true when a drug product, though available in varying strengths, maintains proportional similarity in its active and inactive ingredients. In such cases, the need for in vivo bioequivalence studies for lower strength variants may be waived, provided dissolution tests and in vivo studies on the highest strength yield satisfactory results.Bioequivalence can be indicated through...
Drug Concentrations: Measurements01:23

Drug Concentrations: Measurements

Drug concentration is the quantity of a drug present in a biological sample. Measuring drug amounts in biological samples allows the clinician to understand how a drug is absorbed, distributed, metabolized, and excreted. Samples can be obtained through invasive or non-invasive methods. Invasive techniques involve surgical or parenteral interventions to gather blood, cerebrospinal fluid, or tissue biopsy. Conversely, non-invasive approaches provide samples like urine, feces, and saliva.
Plasma —...
Errors occurring during blood pressure monitoring01:25

Errors occurring during blood pressure monitoring

Blood pressure monitoring is a crucial clinical procedure in diagnosing and managing various cardiovascular conditions. Despite its significance, the accuracy of blood pressure measurements can be compromised by multiple factors, potentially leading to either falsely high or low readings. These inaccuracies are critical as they can significantly impact patient care. So, it is vital to understand these challenges deeply and adopt strategic approaches to minimize errors.
Several factors...
Pre-Procedural Guidelines for Assessing Blood Pressure01:10

Pre-Procedural Guidelines for Assessing Blood Pressure

Accurate blood pressure assessment is crucial for diagnosing and managing various health conditions. To ensure the reliability of these measurements, healthcare professionals must adhere to standardized pre-procedural guidelines. These guidelines enhance patient safety and improve the overall quality of healthcare. The following steps are essential for obtaining accurate and consistent blood pressure readings, from using the appropriate tools to ensuring effective communication with the patient.

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

[A story of respiratory genes].

Revue des maladies respiratoires·2012
Same author

Ventilatory response to exercise does not evidence electroencephalographical respiratory-related activation of the cortical premotor circuitry in healthy humans.

Acta physiologica (Oxford, England)·2012
Same author

[Physical activity and exercise training for patients with cystic fibrosis].

Revue des maladies respiratoires·2010
Same author

Multicentre trial evaluating alveolar NO fraction as a marker of asthma control and severity.

Allergy·2009
Same author

Nandrolone excretion in sedentary vs physically trained young women.

Scandinavian journal of medicine & science in sports·2009
Same author

[Exercise testing in patients with cystic fibrosis].

Revue de pneumologie clinique·2008
Same journal

[French version of the guidelines for connective tissue disease-associated ILD].

Revue des maladies respiratoires·2026
Same journal

[Pulmonary expression of an asymptomatic lysosomal storage disorder].

Revue des maladies respiratoires·2026
Same journal

[Factors associated with FEV1 evolution in cystic fibrosis patients treated by CFTR modulator tritherapy].

Revue des maladies respiratoires·2026
Same journal

[Subacute pulmonary coccidioidomycosis: A differential diagnosis of lung cancer].

Revue des maladies respiratoires·2026
Same journal

[Relevance of the ACT score in severe asthma with obesity: A pilot study].

Revue des maladies respiratoires·2026
Same journal

[Automated analysis of mandibular movements for the screening of obstructive sleep apnea].

Revue des maladies respiratoires·2026
See all related articles

Related Experiment Video

Updated: Jun 21, 2026

Absolute Quantification of Aβ1-42 in CSF Using a Mass Spectrometric Reference Measurement Procedure
08:40

Absolute Quantification of Aβ1-42 in CSF Using a Mass Spectrometric Reference Measurement Procedure

Published on: March 21, 2017

[A plea for adequate reference values]

A Denjean

    Revue Des Maladies Respiratoires
    |July 23, 2009
    PubMed
    Summary

    No abstract available in PubMed .

    More Related Videos

    Selected Reaction Monitoring Mass Spectrometry for Absolute Protein Quantification
    09:04

    Selected Reaction Monitoring Mass Spectrometry for Absolute Protein Quantification

    Published on: August 17, 2015

    Related Experiment Videos

    Last Updated: Jun 21, 2026

    Absolute Quantification of Aβ1-42 in CSF Using a Mass Spectrometric Reference Measurement Procedure
    08:40

    Absolute Quantification of Aβ1-42 in CSF Using a Mass Spectrometric Reference Measurement Procedure

    Published on: March 21, 2017

    Selected Reaction Monitoring Mass Spectrometry for Absolute Protein Quantification
    09:04

    Selected Reaction Monitoring Mass Spectrometry for Absolute Protein Quantification

    Published on: August 17, 2015