Related Experiment Video
Updated: Jun 21, 2026

An Affordable HIV-1 Drug Resistance Monitoring Method for Resource Limited Settings
Published on: March 30, 2014
EDTA sample contamination is common and often undetected, putting patients at unnecessary risk of harm
C L Sharratt1, C J Gilbert, M C Cornes
1Department of Clinical Chemistry, New Cross Hospital, Royal Wolverhampton Hospitals Trust, Wednesfield Road, Wolverhampton, West Midlands, UK. carolinesharratt@doctors.org.uk
Background:
Potassium ethylenediaminetetraacetic acid (EDTA) is a sample tube anticoagulant used for many laboratory analyses. Gross potassium EDTA contamination of blood samples is easily recognised by marked hyperkalaemia and hypocalcaemia. However, subtle contamination is a relatively common, often unrecognised erroneous cause of spurious hyperkalaemia. Potassium EDTA contamination may also cause hypomagnesaemia and hypozincaemia. There are, however, no data on the prevalence of EDTA contamination as a cause of hypocalcaemia, hypomagnesaemia and hypozincaemia.
Methods:
Following a recent service evaluation, we measure EDTA in serum samples from patients with unexplained hyperkalaemia (serum potassium > 6.0 mmol/l). In addition, over a 1-month period EDTA concentrations were measured in hypocalcaemic (serum adjusted calcium < 2.0 mmol/l), hypomagnesaemic (serum magnesium < 0.7 mmol/l) and hypozincaemic (serum zinc < 11 micromol/l) serum samples.
Results:
Ethylenediaminetetraacetic acid contamination was detected in 31 samples, nine of which were detected by our routine screening programme. The remaining 22 samples represented 14.3% (19/133) of hypocalcaemic samples, 4.8% (5/104) of hypomagnesaemic samples and 1.4% (2/139) of hypozincaemic samples. A total of 25/31 (80.6%) of patients were re-bled, of which 23/25 (92%) results normalised.
Conclusions:
Factitious hyperkalaemia, hypocalcaemia and hypomagnesaemia caused by potassium EDTA contamination in our studies are relatively common, and if unrecognised may adversely affect patient care and waste scarce healthcare resources. Correct order of draw of blood samples, improved education and routine laboratory screening of EDTA are necessary to prevent and identify EDTA contamination.
Related Concept Videos
Effects of EDTA on End-Point Detection Methods
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a result, EDTA...
Masking and Demasking Agents
There are many masking agents, such as cyanide, fluoride, triethanolamine, thiourea, and 2,3-bis(sulfanyl)propan-1-ol (formerly 2,3-dimercapto-1-propanol), with the masking agent chosen based on the metal...
EDTA: Direct, Back-, and Displacement Titration
Direct titration involves buffering the metal ion solution to the desired pH and directly titrating with standard EDTA until the endpoint. The optimum pH ensures a large conditional formation constant of metal−EDTA and visibility of the free indicator color in the solution. In addition, auxiliary complexing reagents are used to prevent the precipitation of metal hydroxides and...
EDTA: Indirect and Alkalimetric Titration
EDTA: Auxiliary Complexing Reagents
EDTA: Chemistry and Properties