Chromatographic Fingerprinting by Template Matching for Data Collected by Comprehensive Two-Dimensional Gas Chromatography
Published on: September 2, 2020
Peak modeling approach to accurate assignment of first-dimension retention times in comprehensive two-dimensional
Jacqui L Adcock1, Mike Adams, Blagoj S Mitrevski
1Australian Centre for Research on Separation Science, School of Applied Sciences, RMIT University, GPO Box 2476 V, Melbourne, Victoria 3001, Australia.
Abstract:
Modeling of first-dimension retention of peaks based on modulation phase and period allows reliable prediction of the modulated peak distributions generated in the comprehensive two-dimensional chromatography experiment. By application of the inverse process, it is also possible to use the profile of the modulated peaks (their heights or areas) to predict the shape and parameters of the original input chromatographic band (retention time, standard deviation, area) for the primary column dimension. This allows an accurate derivation of the first-dimension retention time (RSD 0.02%) which is equal to that for the non-modulated experiment, rather than relying upon the retention time of the major modulated peak generated by the modulation process (RSD 0.16%). The latter metric can produce a retention time that differs by at least the modulation period employed in the experiment, which displays a discontinuity in the retention time vs modulation phase plot at the point of the 180 degrees out-of-phase modulation. In contrast, the new procedure proposed here gives a result that is essentially independent of modulation phase and period. This permits an accurate value to be assigned to the first-dimension retention. The proposed metric accounts for the time on the second-dimension, the phase of the distribution, and the hold-up time that the sampled solute is retained in the modulating interface. The approach may also be based on the largest three modulated peaks, rather than all modulated peaks. This simplifies the task of assigning the retention time with little loss of precision in band standard deviation or retention time, provided that these peaks are not all overloaded in the first or second dimension.
More Related Videos
Related Concept Videos
Chromatographic Methods: Terminology
Chromatographic Resolution
The effectiveness of separation can be evaluated by determining the level of separation between two neighboring peaks in a chromatogram, which represents the individual components of a sample.
In chromatography,...
Silica Gel Column Chromatography: Overview
Polar components tend to bind strongly to the silica gel, causing them to move slowly through the column. In contrast, nonpolar compounds...
Chromatography: Introduction
The phase in which the compounds linger or on which the compounds adsorb is called the stationary phase, whereas the mobile phase is the solvent that carries the solutes to be analyzed. In traditional column chromatography, the mixture flows through the stationary phase, and the compounds partition between the stationary and mobile phases...
Column Efficiency: Rate Theory
During elution, a solute molecule experiences numerous transitions between stationary and mobile phases, exhibiting irregular residence times in...
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...