Related Experiment Video
Updated: May 29, 2026

Matrix-assisted Laser Desorption/Ionization Time of Flight (MALDI-TOF) Mass Spectrometric Analysis of Intact Proteins Larger than 100 kDa
Published on: September 9, 2013
Distinct features of matrix-assisted 6 microm infrared laser desorption/ionization mass spectrometry in biomolecular
Michiko Tajiri1, Takae Takeuchi, Yoshinao Wada
1Department of Molecular Medicine, Osaka Medical Center and Research Institute for Maternal and Child Health, 840 Murodo-cho Izumi, Osaka 594-1101, Japan.
Abstract:
Midinfrared-matrix-assisted laser desorption/ionization mass spectrometry (mid-IR-MALDI MS) with a laser emission in the 6 microm wavelength range, which utilizes energy absorption at the C=O double-bond stretch region, was applied to biomolecular analysis. The softness of IR-MALDI MS was evident in the negative ion mode yielding clean mass spectra of [M - H](-) ions for acidic biomolecules with sulfate, phosphate, or carboxylate groups, resulting in better sensitivity than ultraviolet (UV)-MALDI MS. There was no substantial loss of sialic acid due to the prompt fragmentation occurring in IR-MALDI of sialylated glycoconjugates such as gangliosides. Furthermore, the advantage of the low photon energy of IR is that, for the first time, intact protonated molecules of S-nitrosylated peptides can be detected by MALDI MS. In the analysis of redox-sensitive molecules including methylene blue and riboflavin, reductive hydrogenation was minimal, suggesting few hydrogen radicals to have formed in the plume, in contrast to UV-MALDI. In conjunction with a potent new matrix, oxamide, requiring smaller laser fluence, distinct features of the 6 microm IR wavelength range are anticipated to remove one of the limitations of MALDI MS for biomolecular analysis.
More Related Videos
09:38Dithranol as a Matrix for Matrix Assisted Laser Desorption/Ionization Imaging on a Fourier Transform Ion Cyclotron Resonance Mass Spectrometer
Published on: November 27, 2013
10:47Whole-body Mass Spectrometry Imaging by Infrared Matrix-assisted Laser Desorption Electrospray Ionization (IR-MALDESI)
Published on: March 24, 2016
Related Concept Videos
MALDI-TOF Mass Spectrometry
Peptide Identification Using Tandem Mass Spectrometry
This technique helps gather information regarding the protein from which the peptide was obtained and to study the peptides’ amino acid sequence. Identifying peptides from a complex mixture is an important component of the growing field of...
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Tandem Mass Spectrometry
Matrix-Assisted Laser Desorption Ionization (MALDI)
Rapid Identification of Pathogens