Related Experiment Video
Updated: Jun 21, 2026

Ice Generation and the Heat and Mass Transfer Phenomena of Introducing Water to a Cold Bath of Brine
Published on: March 13, 2017
The effect of quantity of ice and size of contact area on ice pack/skin interface temperature
1Department of Physical Therapy, Faculty of Allied Health Sciences, Chulalongkorn University, Bangkok 10330, Thailand. prawit.j@chula.ac.th
Objective:
To determine the effect of quantity of ice and contact area on ice pack/skin interface temperature during a 20-minute cooling period.
Design:
Repeated measures.
Setting:
Laboratory setting in an educational institution.
Participants:
Twenty healthy males aged between 18 and 22 years.
Interventions:
An ice pack was applied to the right thigh with compression using an elastic bandage. The effects of three packs measuring 18 cm x 23 cm containing 0.3, 0.6 and 0.8 kg of ice, and one pack measuring 20 cm x 25 m containing 0.6 kg of ice were compared.
Main Outcome Measure:
The reduction in temperature at the ice pack/skin interface during 20-minute ice applications was monitored at 1-minute intervals.
Results:
The application of 0.8-kg and 0.6-kg ice packs led to a significantly greater decrease in the interface temperature compared with the 0.3-kg ice pack [0.8 kg vs. 0.3 kg: -2.35 degrees C, 95% confidence interval (CI) of the difference -3.36 to -1.34 degrees C; 0.6 kg vs. 0.3 kg: -2.95 degrees C, 95% CI -4.07 to -1.83 degrees C]. No significant difference in temperature was found between the 0.6-kg and 0.8-kg ice packs (0.8 kg vs. 0.6 kg: 0.6 degrees C, 95% CI -0.12 to 1.32 degrees C, P>0.05). The size of the contact area did not alter the degree of cooling significantly (difference between smaller and larger pack: 0.05 degrees C, 95% CI -0.93 to 1.03 degrees C, P>0.05). The lowest temperature during ice application was reached after 8-9 minutes of cooling.
Conclusion:
Application of an ice pack containing at least 0.6 kg of ice leads to a greater magnitude of cooling compared with application of a 0.3-kg ice pack, regardless of the size of the contact area. Thus, clinicians should consider using ice packs weighing at least 0.6 kg for cold treatment.
Related Concept Videos
Decreased Body Temperature
Mechanisms of Heat Transfer I
Factors Affecting Body Temperature
Factors may include:
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Mechanism of heat transfer