Related Experiment Video
Updated: Jun 21, 2026

A Method for Evaluating Timeliness and Accuracy of Volitional Motor Responses to Vibrotactile Stimuli
Published on: August 2, 2016
Design, construction, and validation of an MRI-compatible vibrotactile stimulator intended for clinical use
M Mallar Chakravarty1, Scott Broadbent, Pedro Rosa-Neto
1McConnell Brain Imaging Centre, Montréal Neurological Institute, 3801 University St., Montréal, Canada H3A 2B4. mallar@bic.mni.mcgill.ca
Abstract:
Vibrotactile stimulation has been used successfully to activate the human somatosensory pathway in functional magnetic resonance imaging (fMRI) experiments. The design and characterization of these devices are of particular interest in frequency discrimination tasks and investigations of the somatopic organization of sensory areas. However, few have investigated the utility of vibrotactile stimulation in a clinical context. We have previously demonstrated that vibrotactile stimulation can provide robust activations in areas targeted in stereotactic functional neurosurgical procedures used for tumour resection (i.e.: primary and secondary somatosensory areas) and subcortical targets for thalamic pain and movement disorders (i.e.: sensory thalamus). The main contribution of this manuscript is the presentation of the design, materials, construction, and validation of a novel vibrotactile stimulator intended for clinical use. The thalamic activations are also compared to a digital atlas in order to evaluate anatomical localization. The proposed stimulator was constructed entirely from non-ferromagnetic parts, uses compressed air to deliver stimulation using computer control, and stimulates the entirety of the hand and fingers to ensure robust somatosensory activations. In addition, this stimulator is constructed entirely from "off-the-shelf" parts and would be easily replicated due to the simplicity of design and the relatively small expense of the parts required. The device was tested by stimulating the right hand of 10 normal controls (5 females, 5 males, all right handed; age range: 25-42 years, mean: 30.9 years, standard deviation: 5.2 years) during an fMRI experiment. The results demonstrate significant single subject activations of primary and secondary somatosensory cortices and of the sensory thalamus.
More Related Videos
07:34Functional MRI in Conjunction with a Novel MRI-compatible Hand-induced Robotic Device to Evaluate Rehabilitation of Individuals Recovering from Hand Grip Deficits
Published on: November 23, 2019
05:43Applying Incongruent Visual-Tactile Stimuli during Object Transfer with Vibro-Tactile Feedback
Published on: May 23, 2019