Related Experiment Video
Updated: Jun 21, 2026

Post Column Derivatization Using Reaction Flow High Performance Liquid Chromatography Columns
Published on: April 26, 2016
Capillary chromatography based on tube radial distribution of aqueous-organic mixture carrier solvents
Naoya Jinno1, Minoru Itano, Masahiko Hashimoto
1Department of Chemical Engineering and Materials Science, Faculty of Science and Engineering, Doshisha University, Kyotanabe, Kyoto, Japan.
Abstract:
A capillary chromatography system was developed using open capillary tubes made of fused-silica, polyethylene, or poly(tetrafluoroethylene), and an aqueous-organic mixture (water-acetonitrile-ethyl acetate mixture) as a carrier solution. Model analyte mixture solutions, such as 2,6-naphthalenedisulfonic acid and 1-naphthol, Eosin Y and perylene, bis[N,N-bis(carboxymethyl)aminomethyl]fluorescein and 1,1'-bi-2-naphthol, and 2,7-naphthalenedisulfonic acid and p-nitroaniline, were injected into the capillary tube by a gravity method. The analyte solutions were subsequently delivered through the capillary tube with the carrier solution by a micro-syringe pump. The system worked under laminar flow conditions. The analytes were separated through the capillary tube and detected on-capillary by an absorption detector. For example, 2,6-naphthalenedisulfonic acid and 1-naphthol were detected in this order with a carrier solution of water-acetonitrile-ethyl acetate (volume ratio 15:3:2), while they were detected in the reverse order with a carrier solution of water-acetonitrile-ethyl acetate (volume ratio 2:9:4). The other analyte solutions were similarly separated by the system. The elution times of the analytes could be easily reversed by changing the component ratio of the solvents in the carrier solution.
Related Concept Videos
Chromatography: Introduction
The phase in which the compounds linger or on which the compounds adsorb is called the stationary phase, whereas the mobile phase is the solvent that carries the solutes to be analyzed. In traditional column chromatography, the mixture flows through the stationary phase, and the compounds partition between the stationary and mobile phases...
Analyte Adsorption and Distribution
High-Performance Liquid Chromatography: Elution Process
Ion-Exchange Chromatography
Chromatographic Methods: Classification
Chromatographic techniques are typically named by...
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...

