Aim:
Investigation of the biodistribution and calculation of dosimetry of Ga-68-DOTATOC- for patients imaged in the routine clinical setting for diagnosis or exclusion of neuroendocrine tumours.
Patients, Methods:
Dynamic PET/CT-imaging (Biograph 16) was performed over 20 min in 14 patients (8 men, 6 women) after injection of (112+/-22) MBq 68Ga-DOTATOC followed by whole body 3D-acquisition (8 bed positions, 3 or 4 min each) 30 min p.i. and 120 min p.i.. Urinary tracer elimination was measured and blood activity was derived non-invasively from the blood pool of the heart. The relevant organs for dosimetry were spleen, kidneys, liver, adrenals, urinary bladder and pituitary gland. Dosimetry was performed using OLINDA/EXM 1.0 software and specific organ uptake was expressed as standardized uptake values (SUVs).
Results:
Rapid physiological uptake of the radiotracer could be demonstrated in liver, spleen and kidneys, adrenals and pituitary gland (mean SUVs were 6, 20, 16, 10, and 4, respectively). Radiotracer elimination was exclusively via urine (16% of injected dose within 2h); no redistribution could be observed. The spleen and the kidneys received the highest radiation exposure (0.24 mSv/MBq, 0.22 mSv/MBq resp.), mean effective dose yielded 0.023 mSv/MBq.
Conclusion:
68Ga-DOTATOC is used extensively for diagnosis of somatostatin receptor positive tumours because it has several advantages over the 111In-labelled ligand. The derived dosimetric values are lower than first approximations from the biological data of OctreoScan. The use of CT for transmission correction of the PET data delivers radiation exposure up to 1 mSv (low dose).
Related Concept Videos
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...
Radiological Investigation I: X-ray and CT
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies III: Computed Tomography