A Detailed Protocol for Physiological Parameters Acquisition and Analysis in Neurosurgical Critical Patients
Published on: October 17, 2017
Cardiovascular monitoring: physiological and technical considerations
Andrew B Casabianca1, Daniel E Becker
1Department of Anesthesiology and Surgery, University of Toledo College of Medicine, Toledo, OH, USA.
Abstract:
The American Dental Association and several dental specialty organizations have published guidelines that detail requirements for monitoring patients during various levels of sedation and, in some cases, general anesthesia. In general, all of these are consistent with those guidelines suggested by the American Society of Anesthesiologists Task Force for Sedation and Analgesia by Non-Anesthesiologists. It is well-accepted that the principal negative impact of sedation and anesthesia pertains to the compromise of respiratory function, but attentive monitoring of cardiovascular function is also important. While monitoring per se is a technical issue, an appreciation of its purpose and the interpretation of the information provided require an understanding of basic cardiovascular anatomy and physiology. The focus of this continuing education article is to address essential physiological aspects of cardiovascular function and to understand the appropriate use of monitors, including the interpretation of the information they provide.
Related Concept Videos
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac muscle...
Holter Monitor: 24-Hour Monitoring
Errors occurring during blood pressure monitoring
Several factors...
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Cardiomyopathy VII: Pre and Post Operative Nursing Management