Selective retention of explosives and related compounds on gas-chromatographic capillary columns coated with lanthanide(III) beta-diketonate polymers
Related Experiment Video
Updated: Jun 21, 2026

Quantitative Detection of Trace Explosive Vapors by Programmed Temperature Desorption Gas Chromatography-Electron Capture Detector
Published on: July 25, 2014
Scott D Harvey1, Thomas J Wenzel
1Pacific Northwest National Laboratory, National Security Directorate, MSIN: P7-07, 902 Battelle Boulevard, P.O. Box 999, Richland, WA 99352, USA. scott.harvey@pnl.gov
Abstract:
The purpose of this research was to investigate coating capillary columns with lanthanide(III) beta-diketonate polymers to provide gas-chromatographic columns with selectivity toward explosives and related compounds. Capillary columns were statically coated with a mixture of a lanthanide(III) beta-diketonate polymer, which utilized p-di(4,4,5,5,6,6,6-heptafluoro-1,3-hexanedionyl)benzene (dihed) as a ligand, and SE-30. A novel coating technique was developed that used a methanol-containing azeotrope to provide solubility for both polymers while maintaining a low boiling point compatible with static coating. As based on temperature-programmed retention indices, the experimental columns displayed selective retention of nitroaromatic, nitroalkane, and nitrate ester test probes relative to an appropriate SE-30 control column. Selective retention was more pronounced for strongest Lewis base analyte contained in the test mixture (i.e., cyclohexanone). Relative analyte retention on the La(dihed), Tb(dihed), and Eu(dihed) columns are discussed relative to Lewis acidity and solubility of the polymer in the azeotropic coating solution.
More Related Videos
08:56Detection of Regulated Ergot Alkaloids in Food Matrices by Liquid Chromatography-Trapped Ion Mobility Spectrometry-Time-of-Flight Mass Spectrometry
Published on: November 22, 2024
10:14Chromatographic Fingerprinting by Template Matching for Data Collected by Comprehensive Two-Dimensional Gas Chromatography
Published on: September 2, 2020
Related Concept Videos
Gas Chromatography: Types of Detectors-II
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a column.
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Silica Gel Column Chromatography: Overview
Polar components tend to bind strongly to the silica gel, causing them to move slowly through the column. In contrast, nonpolar compounds...
Ion-Exchange Chromatography