Related Experiment Video
Updated: Jun 21, 2026

Identifying Coronary Artery Calcification on Non-gated Computed Tomography Scans
Published on: August 28, 2018
Accuracy of dual-source computed tomography coronary angiography: evaluation with a standardised protocol for cardiac
Andre Plass1, Naim Azemaj, Hans Scheffel
1Clinic for Cardiovascular Surgery, University Hospital Zurich, Raemistr. 100, 8091 Zurich, Switzerland. Andre.Plass@usz.ch
Background:
This study assesses the accuracy of the new dual-source computed tomography (DSCT) for detection of coronary artery disease (CAD) compared with invasive coronary angiography (ICA) with a specifically designed data presentation protocol for cardiac surgeons.
Methods:
Forty patients (30 males/10 females) underwent ICA and DSCT. Best-quality images were prepared by radiologists. Evaluation of 12 segments of significant coronary stenosis was done by two cardiac surgeons with a data presentation protocol including different coronary views in two-/three-dimensional (2D/3D) images. No beta-blockers were administered prior to DSCT.
Results:
ICA revealed CAD in 21 patients and valvular disease but no CAD in 19 patients. In DSCT, 20/21 patients were diagnosed with CAD (at least one significant stenosis per patient). In 11/21 patients, all 12 segments were assessed correctly; in 7/21 patients one segment and in 3/21 patients two segments were evaluated incorrectly. Of all 21 patients with CAD, 239/252 segments (95%) were correctly evaluated. In 18/19 patients without CAD, DSCT correctly ruled-out the ICA results in 226/228 segments (99%). In total, 465/480 segments were correctly assessed (97%). Of 480 segments, only six were considered not assessable. DSCT assessments of the segments showed a sensitivity of 91%, specificity of 99%, a positive predictive value of 92% and a negative predictive value of 99%.
Conclusions:
The accuracy of DSCT coronary angiography especially for exclusion of CAD is promising. The introduced data presentation protocol allows for the independent evaluation by cardiac surgeons after pre-arrangement from the radiologists.
More Related Videos
06:57Semi-Automatic Graphical Tool for Measuring Coronary Artery Spatially Weighted Calcium Score from Gated Cardiac Computed Tomography Images
Published on: September 22, 2023
06:59Improved Registration of 3D CT Angiography with X-ray Fluoroscopy for Image Fusion During Transcatheter Aortic Valve Implantation
Published on: June 3, 2018
Related Concept Videos
Imaging Studies for Cardiovascular System V: CT
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT
Acute Coronary Syndrome III: Diagnostic Studies
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...