Related Experiment Video
Updated: Jun 21, 2026

Determination of Continuity Index Values in Atrial Fibrillation Ablation with Proactive Esophageal Cooling
Published on: April 19, 2024
High monthly temperature as a possible risk factor of local vascular bleeding complications during percutaneous
Rafał Dabrowski1, Cezary Sosnowski, Ilona Kowalik
12nd Department of Coronary Heart Disease, Institute of Cardiology, Warsaw, Poland. rdabrowski45@gmail.com
Background:
Bleeding complications are a very important issue in the era of percutaneous coronary interventions (PCI). Effective antiplatelet therapy increases the rate of successful interventions but the risk of bleeding complications, among them local vascular complications, may be higher. Other factors may also be important in the development of local bleeding complications.
Aim:
To examine the relationship between air temperature and local haemorrhagic complications.
Methods:
The retrospective analysis of ultrasonographic examinations performed during the last 5 years (2003-2007) in 10 548 consecutive patients undergoing cardiac catheterisation due to acute coronary syndromes or elective coronary angiography was performed. The relationship between mean monthly temperature, other factors and the rate of local bleeding complications was examined.
Results:
Mean number of treated patients was 2708 +/- 377/year (2113-3089), of whom 1692 +/- 362/year had coronary angiography and 1345 +/- 281/year had PCI. Yearly rate of all femoral bleeding complications was 3.0 +/- 0.5%. There were more haematomas than pseudoaneurysms: 2.2 +/- 0.4 vs. 0.8 +/- 0.1%, p < 0.0001. Higher mean monthly air temperatures were positively correlated with the number of complications (r = 0.11, p < 0.05), both in males and females (r = 0.13, p < 0.05). A positive correlation between number of haematomas and air temperature values was detected in women. Yearly rate of all vascular complications, haematomas and pseudoaneurysms was higher in women than in men 4.3 +/- 0.9 vs. 2.3 +/- 0.3% (p < 0.0001), 3.0 +/- 0.7 vs. 1.7 +/- 0.3% (p < 0.0001) and 1.3 +/- 0.2 vs. 0.6 +/- 0.1% (p < 0.0005) respectively. In spite of more aggressive antiplatelet therapy, higher clopidogrel loading doses and abciximab use introduced during the analysed period, the rate of local vascular bleeding complications did not increase.
Conclusions:
High air temperature during the post-intervention period, besides female gender and advanced age, may be another risk factor for local bleeding complications. This risk remains low (3%), in spite of growing intensity of antiplatelet treatment.
Related Concept Videos
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above the...
Peripheral Arterial Disease II: Clinical Manifestations and Diagnostic Evaluation
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's forehead...