Related Experiment Video
Updated: Jun 21, 2026

Three-Dimensional Phase Resolved Functional Lung Magnetic Resonance Imaging
Published on: June 21, 2024
Noncontrast-enhanced three-dimensional magnetic resonance aortography of the thorax at 3.0 T using
Yasuo Amano1, Katsuya Takahama, Shinichiro Kumita
1Department of Radiology, Nippon Medical School, Tokyo, Japan. yas-amano@nifty.com
Objective:
To evaluate the feasibility of a respiratory-compensated three-dimensional (3D) T1-weighted k-space segmented gradient-echo imaging sequence with radial data sampling for noncontrast-enhanced 3D magnetic resonance (MR) aortography of the thorax at 3.0 T.
Materials And Methods:
Twenty-two subjects, including healthy volunteers (n = 6) and patients with suspected diseases of the thoracic aorta (n = 16), underwent noncontrast-enhanced 3D MR aortography at 3.0 T acquired using a navigator- or respiratory-gated 3D T1-weighted k-space segmented gradient-echo imaging sequence with radial data sampling (TR, 4.8 milliseconds; TE, 1.5 milliseconds; flip angle, 20 degrees; spatial resolution 0.66 x 0.76 x 5.6-6.4 mm) in the sagittal oblique imaging plane. ECG gating, fat-suppression, and T2-prepared pulses were employed. The vascular contrast of the thoracic aorta and the contrast ratio between the aorta and the superior vena cava or pulmonary artery were compared between the noncontrast-enhanced 3D MR aortography and transverse two-dimensional (2D) steady-state free precession. Image quality of the noncontrast-enhanced 3D MR aortography was rated on a 4 point scale (1, nondiagnostic, to 4, diagnostic and excellent image quality).
Results:
The noncontrast-enhanced 3D MR aortography provided vascular contrast of the thoracic aorta comparable to, and contrast ratio between the aorta and superior vena cava higher than, those of 2D steady-state free precession. The mean score of image quality of the noncontrast-enhanced 3D MR aortography was 3.0 (diagnostic with no or few artifact), and some major branch arteries were visualized by this imaging.
Conclusion:
Respiratory-compensated 3D T1-weighted k-space segmented gradient-echo imaging with radial data sampling are feasible for the noncontrast-enhanced 3D MR aortography of the thorax at 3.0 T.
Related Concept Videos
Radiological Investigation II: MRI and Ventilation Perfusion Scan
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...
Imaging Studies for Cardiovascular System IV: CMRI
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Magnetic Resonance Imaging
Imaging Studies for Cardiovascular System V: CT
Imaging Studies III: Computed Tomography