Related Experiment Video
Updated: Jun 21, 2026

High-Temperature and High-Pressure In situ Magic Angle Spinning Nuclear Magnetic Resonance Spectroscopy
Published on: October 9, 2020
Signal loss in 1D magic-angle spinning exchange NMR (CODEX): radio-frequency limitations and intermediate motions
Christiane Hackel1, Cornelius Franz, Anja Achilles
1University of Halle, Department of Physics, Halle, Germany.
Abstract:
The popular 1D MAS exchange experiment CODEX suffers limitations due to signal loss during the finite recoupling periods, during which the magnetization evolves in the transverse plane. Here, we address the origins and possible improvements of this problem, aimed at (i) an optimization of the signal-to-noise ratio in the experiments, as well as harnessing intermediate-motion induced signal loss for obtaining approximate information on (ii) correlation times and (iii) potential distributions, where the latter are often found in polymeric systems. First, we show that the intensity of the signal is sensitive to the radiofrequency (rf) parameters of the carbon recoupling and proton decoupling, and care must be taken to gain optimal signal intensity. Optimum conditions are found for recoupling pulses being as short as possible for large chemical shift anisotropy (CSA) values, and approaching a ratio of 3 between the nutation frequencies for protonated carbons, calling for an individual adjustment in each case. Second, we demonstrate that the effect of intermediate motions can be studied semi-quantitatively by combining CODEX data with its constant-time modification CONTRA, which allows for a tuning of the signal loss due to intermediate motions. Third, for the case of samples featuring a distribution of correlation times, we propose a procedure to obtain an estimate of the proportion of molecular segments in the sample for which the CODEX data are representative, i.e., which share of segments moves truly in the slow-motion regime. The procedure involves the combination of CODEX data with a cross-polarisation (CP) reference experiment for an estimate of the full sample magnetization; it is demonstrated on the example of semi-crystalline poly(ethylene oxide).
More Related Videos
06:42Cryogenic Sample Loading into a Magic Angle Spinning Nuclear Magnetic Resonance Spectrometer that Preserves Cellular Viability
Published on: September 1, 2020
14:55Atomic Scale Structural Studies of Macromolecular Assemblies by Solid-state Nuclear Magnetic Resonance Spectroscopy
Published on: September 17, 2017
Related Concept Videos
¹H NMR: Interpreting Distorted and Overlapping Signals
As Δν decreases and the signals move closer, the doublets appear increasingly distorted. The intensities of the inner lines increase at the cost of those of the outer lines as the signals are slanted or...
NMR Spectrometers: Resolution and Error Correction
Double Resonance Techniques: Overview
Spin decoupling is usually achieved by...
¹³C NMR: ¹H–¹³C Decoupling
A broadband decoupling technique is used to simplify these complex, sometimes overlapping, signals. Broadband decoupling relies on a...
NMR Spectroscopy: Spin–Spin Coupling
Atomic Nuclei: Magnetic Resonance