Related Experiment Video
Updated: Jun 21, 2026

In vitro Assessment of Aortic Regurgitation Using Four-Dimensional Flow Magnetic Resonance Imaging
Published on: February 25, 2022
Comprehensive assessment of the severity and mechanism of aortic regurgitation using multidetector CT and MR
Céline Goffinet1, Valérie Kersten, Anne-Catherine Pouleur
1Cardiology Division, Cliniques Universitaires St. Luc UCL, Av Hippocrate 10/2806, 1200, Woluwe St. Lambert, Belgium.
Abstract:
Recent studies have suggested that both cardiac magnetic resonance (MR) and multidetector computed tomography (MDCT) can quantify aortic regurgitation (AR) by planimetry of the anatomical regurgitant orifice (ARO). However, this measurement was not compared with quantitative assessment of AR such as the effective regurgitant orifice (ERO) by proximal isosurface area (PISA) transthoracic echocardiography (TTE) or phase contrast MR. In 42 patients (34 men, age 54 +/- 11 years) we compared planimetered ARO by MDCT and MR with ERO and regurgitant volume by PISA TTE and phase contrast MR. ARO by MDCT (r = 0.87, p < 0.001) and MR (r = 0.81, p < 0.001) correlated highly with ERO by TTE. However, ARO by MDCT (27 +/- 15 mm(2), p < 0.001), but not by MR (23 +/- 13 mm(2), p = 0.58), were larger than PISA ERO (22 +/- 11 mm(2)). ARO by MDCT (r = 0.78, p < 0.001; r = 0.85, p < 0.001) and MR (r = 0.85, p < 0.001; r = 0.87 p < 0.001) correlated well with regurgitant volume by PISA and phase contrast MR. Both MDCT (small ka, Cyrillic = 0.80, p < 0.001) and MR (small ka, Cyrillic = 0.84, p < 0.001) demonstrated excellent agreement in correctly assessing the mechanisms of AR, i.e. aortic root dilatation (type I), cusp prolapse (type II) and restrictive cusp motion (type III), using surgical inspection as a reference. Measurement of ARO by both MDCT and MR allows accurate quantitative assessment of AR. Both techniques can also accurately determine the mechanism of AR.
More Related Videos
09:32Time-Resolved, Dynamic Computed Tomography Angiography for Characterization of Aortic Endoleaks and Treatment Guidance via 2D-3D Fusion-Imaging
Published on: December 9, 2021
07:42An Image Guided Transapical Mitral Valve Leaflet Puncture Model of Controlled Volume Overload from Mitral Regurgitation in the Rat
Published on: May 19, 2020
Related Concept Videos
Aortic Regurgitation II: Clinical Features and Diagnostic Tests
Mitral Regurgitation II: Clinical Features and Diagnostic Tests
Aortic Regurgitation I: Introduction
Aortic Regurgitation III: Medical Management
Aortic Regurgitation IV: Nursing Management
Mitral Regurgitation III: Medical Management