Evaluation of air handling in a new generation neonatal oxygenator with integral arterial filter
D Gomez1, T J Preston, V F Olshove
1Department of Cardiovascular Perfusion, The Heart Center, Nationwide Children's Hospital, Columbus, Ohio 43205, USA. Daniel.Gomez@NationwideChildrens.org
Abstract:
Prime volume of the cardiopulmonary bypass circuit may lead to significant hemodilution and the potential need for blood products for all patients, but may be more critical in the pediatric and, specifically, the neonatal patient. We report on the first use of the Terumo CAPIOX FX05 (Baby-FX) oxygenator with integral arterial filter, prime volume 43 ml, evaluating performance and air-handling of six Baby-FX versus thirteen Baby-RX oxygenators. The Terumo Baby-FX primes and performs as easily as the Baby-RX series. A significant prime component in the neonatal CPB circuit can be the arterial line filter (ALF). Removal of the ALF may lead to significant reduction in prime volume, decreased exposure to foreign surfaces with subsequent reduction in inflammation, and potential elimination or reduction in blood product exposures.
More Related Videos
05:45Delivery of In Vivo Acute Intermittent Hypoxia in Neonatal Rodents to Prime Subventricular Zone-derived Neural Progenitor Cell Cultures
Published on: November 2, 2015
05:46A Novel Inhalation Mask System to Deliver High Concentrations of Nitric Oxide Gas in Spontaneously Breathing Subjects
Published on: May 4, 2021
Related Concept Videos
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...
Respiratory Assessment: Purpose and Indications
Objectives and Importance:
The primary goal of respiratory assessment is to evaluate patients at early risk of clinical deterioration. Since respiratory distress often precedes other signs of declining health, breathing patterns and sounds become a...
Oxygen Delivering System III: Tracheostomy and T-piece
Tracheostomy
A tracheostomy is a surgically created opening (stoma) in the anterior part of the trachea. It is used to establish a patient airway, bypass an upper airway obstruction, simplify the removal of secretions, permit long-term...
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation (NIPPV)
Administering Oxygen by Mask
Administering oxygen by mask is a common nursing intervention that provides supplemental oxygen to patients with respiratory distress or chronic lung conditions. This procedure involves delivering oxygen at a specified rate through a face mask connected to an oxygen source.
Equipment
The equipment necessary for this procedure includes: