Shear bond strengths to dentin and fluoride release from fluoride-containing liners
Related Experiment Video
Updated: Oct 17, 2026

Microhardness Measurements on Tooth and Alveolar Bone in Rodent Oral Disease Models
Published on: April 26, 2024
S Strickland1, D H Retief, C M Russell
1University of Alabama School of Dentistry, Birmingham.
Abstract:
The purpose of this study was to determine the shear bond strengths of five commercially available fluoride-containing restorative systems to dentin and to evaluate the fluoride release from them. The five systems evaluated were: (A) Vitrabond/Silux; (B) Zionomer Powder Liquid/Perfection; (C) Zionomer Paste Paste/Perfection; (D) TimeLine/Prisma-Fil; and (E) GC Dental Cement/Fuji II. Eighteen test specimens were prepared on the dentin surfaces of extracted human permanent first and second molars ground on 600 grit SiC paper with each system. The bonded cylinders were removed from the assembly apparatus 15 minutes after cure, stored in physiological saline at 37 degrees C for 24 hours and subjected to a shear load at 0.5 mm/min. Five cylindrical specimens were prepared for each system, the discs were suspended in 25 microL glass distilled water and the fluoride release (microgram F/mm2) determined at daily intervals for 15 days and then after 30 and 90 days. The data were analyzed by a one-way analysis of variance and Duncan's multiple range test. The following shear bond strengths (Mean +/- SD) were recorded (MPa): A: 8.86 +/- 1.49; B: 4.24 +/- 1.23; C: 4.41 +/- 1.39; D: 3.85 +/- 1.60; E: 4.81 +/- 1.21. With all the systems, the fluoride release dropped sharply during the first 7 days and then remained constant. The shear bond strength and the fluoride release from Vitrabond/Silux were significantly greater than that of the other systems.
More Related Videos
07:42Quasistatic Mechanical Testing for Computer-Aided Design and Manufacturing Occlusal Veneers Cemented to Milled Dentin Analog Material
Published on: December 20, 2024
04:23Standardized Protocol to Evaluate the Effect of Surface Treatments, Luting Cements, and Thermocycling on PEEK–Composite Bond Strength
Published on: June 9, 2026
Related Concept Videos
Valence Bond Theory
Chemical Bonds
Atoms participate in a chemical bond formation to acquire a completed valence-shell electron configuration similar to that of the noble gas nearest to it in atomic number. Ionic, covalent, and metallic bonds are some of the important types of chemical bonds. Bond energy and bond length determine the strength of a chemical bond.
Types of Chemical Bonds
An ionic bond is formed due to electrostatic attraction between cations and anions. Often, the ions are formed by the transfer of electrons from...
Hydrogen Bonds
Mortar Properties
Strength of Cement
For compressive strength tests, ASTM C 109-05 standards prescribe a cement-sand mix ratio of 1:2.75 and a water/cement ratio of 0.485 for making 2-inch cubes. These cubes are mixed, cast, and cured in saturated lime water at 23°C until testing. Flexural strength testing, outlined in ASTM C...
Bonding and Strength of Aggregate