Aortic Pulse Wave Analysis is not a surrogate for central arterial Pulse Wave Velocity

Alvaro N Gurovich1, Darren T Beck, Randy W Braith

  • 1Center for Exercise Science, Department of Applied Physiology and Kinesiology, College of Health and Human Performance, University of Florida, PO Box 118206, Gainesville, FL 32611, USA. algurov@hhp.ufl.edu

Insights

Pulse Wave Analysis (PWA) cannot reliably predict Pulse Wave Velocity (PWV), the gold standard for arterial stiffness. This study found PWA parameters did not significantly correlate with PWV, limiting its use as a surrogate measure.

Area of Science:

  • Cardiovascular Physiology
  • Biomedical Engineering
  • Clinical Diagnostics

Background:

  • Arterial stiffness (AS) is a key cardiovascular risk factor, impacting myocardial oxygen demand and coronary perfusion.
  • Pulse Wave Velocity (PWV) is the gold standard for AS assessment but is clinically impractical.
  • Pulse Wave Analysis (PWA) offers a potentially more accessible method for evaluating arterial properties.

Purpose of the Study:

  • To investigate if PWA parameters derived from applanation tonometry can predict central aortic PWV.
  • To assess the clinical utility of PWA as a surrogate for PWV measurement.

Main Methods:

  • Radial artery PWA and aortic PWV measurements were conducted on 77 healthy subjects.
  • Statistical analyses included correlation matrices and stepwise multiple regression.
  • Bland-Altman analysis was used to evaluate agreement between measured and predicted PWV.

Main Results:

  • No significant correlations were found between PWV and PWA parameters.
  • The developed regression model (PWV = 1.76 + 0.044*Age + 0.023*SBP) explained only 28% of PWV variability.
  • The Bland-Altman test revealed no agreement between measured and predicted PWV.

Conclusions:

  • PWA parameters derived from applanation tonometry are not suitable as surrogate measures for assessing aortic PWV.
  • Clinical application of PWA for predicting arterial stiffness requires further validation and development.
  • Current PWA methods do not provide sufficient accuracy to replace gold-standard PWV measurements.

Related Concept Videos

Pulse01:16

Pulse

When the heart pumps blood out, arterial elastic fibers play a crucial role in sustaining a high-pressure gradient. They expand to accommodate the received blood and then recoil - a process known as the pulse that can be either manually palpated or electronically quantified. Despite a reduction in its effect with increased distance from the heart, elements of the pulse's systolic and diastolic components persist, observable even at the arteriole level.
The pulse serves as a clinical indicator...
Pulse01:05

Pulse

The pulse is one of the most fundamental physiological indicators of the body's cardiovascular health. It is the rhythmic expansion and contraction of the arterial walls in response to the pressure generated by the heart's pumping action.
Pulse Rate and its Significance
Pulse rate, often measured in beats per minute (bpm), reflects the heart rate (HR), which is influenced by numerous factors such as stress, physical activity, and hormonal changes. A normal resting adult pulse rate falls between...
Special considerations while measuring pulse01:13

Special considerations while measuring pulse

Assessing a patient's pulse is a fundamental skill in healthcare, but certain situations require special attention:
Pulse amplitude and quality01:17

Pulse amplitude and quality

Pulse amplitude is a crucial indicator of cardiac health because it provides valuable insights into the strength of left ventricular contractions and the overall uniformity of blood circulation within the vasculature. The strength of the pulse is directly related to the force with which the heart contracts and the volume of blood being pumped.
A weak or absent pulse may indicate reduced cardiac output or poor left ventricular contraction, which can be signs of cardiovascular dysfunction or...
Assessment of apical radial pulse01:25

Assessment of apical radial pulse

Apical-Radial (A-R) Pulse Assessment
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation
Assessment of apical pulse01:17

Assessment of apical pulse

Assessing the Apical Pulse
Assessing the apical pulse is a critical nursing procedure, particularly indicated for: