Pulse wave velocity and digital volume pulse as indirect estimators of blood pressure: pilot study on healthy
Juan M Padilla1, Enrique J Berjano, Javier Sáiz
1Institute for Research and Innovation on Bioengineering (I3BH), Universidad Politécnica de Valencia, Valencia, Spain.
Abstract:
The purpose of the study was to asses the potential use of pulse wave velocity (PWV) and digital volume pulse (DVP) as estimators of systolic (SBP) and diastolic (DPB) blood pressure. Single and multiple correlation studies were conducted, including biometric parameters and risk factors. Brachial-ankle PWV (baPWV) and DVP signals were obtained from a Pulse Trace PWV and Pulse Trace PCA (pulse contour analysis), respectively. The DVP (obtained by photoplethysmography), allowed stiffness (SI) and reflection indexes (RI) to be derived. The first study on 47 healthy volunteers showed that both SBP and DPB correlated significantly both with baPWV and SI. Multiple regression models of the baPWV and the waist-to-hip ratio (WHR) allowed SBP and DBP to be modeled with r = 0.838 and r = 0.673, respectively. SI results also employed WHR and modeled SBP and DBP with r = 0.852 and r = 0.663, respectively. RI did not correlate either with SBP or DBP. In order to avoid the use of ultrasound techniques to measure PWV, we then developed a custom-built system to measure PWV by photoplethysmography and validated it against the Pulse Trace. With the same equipment we conducted a second pilot study with ten healthy volunteers. The best SBP multiple regression model for SBP achieved r = 0.997 by considering the heart-finger PWV (hfPWV measured between R-wave and index finger), WHR and heart rate. Only WHR was significant in the DBP model. Our findings suggest that the hfPWV photoplethysmography signal could be a reliable estimator of approximate SBP and could be used, for example, to monitor cardiac patients during physical exercise sessions in cardiac rehabilitation.
More Related Videos
06:04Pulse-Wave Velocity, Flow-Mediated Dilation, and Carotid Intima-Media Thickness to Assess Cardiovascular Risk in Population with Metabolic Syndrome
Published on: September 27, 2024
05:51Measuring the Carotid to Femoral Pulse Wave Velocity (Cf-PWV) to Evaluate Arterial Stiffness
Published on: May 3, 2018
Related Concept Videos
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Pulse
The pulse serves as a clinical indicator...
Pulse
Pulse Rate and its Significance
Pulse rate, often measured in beats per minute (bpm), reflects the heart rate (HR), which is influenced by numerous factors such as stress, physical activity, and hormonal changes. A normal resting adult pulse rate falls between...
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...