Related Experiment Video
Updated: Jun 21, 2026

Developing a Salivary Antibody Multiplex Immunoassay to Measure Human Exposure to Environmental Pathogens
Published on: September 12, 2016
Matrix effects on an antigen immobilized format for competitive enzyme immunoassay of salivary testosterone
1Health and Food Group, The New Zealand Institute For Plant & Food Research Limited, Private Bag 3123, Hamilton, New Zealand. jmitchell@hortresearch.co.nz
Matrix interferences in salivary testosterone enzyme immunoassays are important in the development of direct ELISA. An alternative format for sensitive enzyme immunoassay of testosterone was developed using immobilization of the antigen as part of a protein conjugate using oligoethylene glycol linker to project the antigen, with color development via enzyme labeled secondary antibody. This technique gave the required sensitivity for detection of testosterone from male saliva with a limit of detection (LOD) of 8.9 pg/mL (31 pmol/L). Application of the immunoassay directly in human saliva gave suppression of binding signals for the samples, indicating clear matrix interference with antibody binding. A wide variety of treatments were used in an attempt to overcome this effect, including use of both synthetic saliva and stripped human saliva for standard preparation, use of bovine serum albumin (BSA) to reduce non-specific binding of contaminants, pH adjustment of samples and/or standards and use of different antibodies. None of these techniques proved effective, causing either substantial suppression or enhancement of signal, and dilution was not possible because of the very low physiological concentrations. Complete removal of the saliva medium by chemical extraction was the only technique studied that could overcome this problem. These issues have not been explored previously for direct ELISA of salivary testosterone using alternative assay formats and have implications for the design of small molecule plate-based immunoassays in this medium.
Matrix interferences in salivary testosterone enzyme immunoassays are important in the development of direct ELISA. An alternative format for sensitive enzyme immunoassay of testosterone was developed using immobilization of the antigen as part of a protein conjugate using oligoethylene glycol linker to project the antigen, with color development via enzyme labeled secondary antibody. This technique gave the required sensitivity for detection of testosterone from male saliva with a limit of detection (LOD) of 8.9 pg/mL (31 pmol/L). Application of the immunoassay directly in human saliva gave suppression of binding signals for the samples, indicating clear matrix interference with antibody binding. A wide variety of treatments were used in an attempt to overcome this effect, including use of both synthetic saliva and stripped human saliva for standard preparation, use of bovine serum albumin (BSA) to reduce non-specific binding of contaminants, pH adjustment of samples and/or standards and use of different antibodies. None of these techniques proved effective, causing either substantial suppression or enhancement of signal, and dilution was not possible because of the very low physiological concentrations. Complete removal of the saliva medium by chemical extraction was the only technique studied that could overcome this problem. These issues have not been explored previously for direct ELISA of salivary testosterone using alternative assay formats and have implications for the design of small molecule plate-based immunoassays in this medium.
More Related Videos
08:50Multiplexed Fluorescent Microarray for Human Salivary Protein Analysis Using Polymer Microspheres and Fiber-optic Bundles
Published on: October 10, 2013
06:15Characterization of Thymus-dependent and Thymus-independent Immunoglobulin Isotype Responses in Mice Using Enzyme-linked Immunosorbent Assay
Published on: September 7, 2018