Use of Two Intracorporeal Ventricular Assist Devices As a Total Artificial Heart
Published on: May 11, 2018
Single-centre experience with the Thoratec paracorporeal ventricular assist device for patients with primary cardiac
Matthias Kirsch1, Emmanuelle Vermes, Thibaud Damy
1Service de chirurgie thoracique et cardiovasculaire, hôpital Henri-Mondor, AP-HP, 51, avenue du Maréchal-de-Lattre-de-Tassigny, 94000 Créteil cedex, France. matthias.kirsch@hmn.aphp.fr
Background:
Temporary mechanical circulatory support may be indicated in some patients with cardiac failure refractory to conventional therapy, as a bridge to myocardial recovery or transplantation.
Aims:
To evaluate outcomes in cardiogenic shock patients managed by the primary use of a paracorporeal ventricular assist device (p-VAD).
Methods:
We did a retrospective analysis of demographics, clinical characteristics and survival of patients assisted with a Thoratec p-VAD.
Results:
p-VADs were used in 84 patients with cardiogenic shock secondary to acute myocardial infarction (35%), idiopathic (31%) or ischaemic (12%) cardiomyopathy, myocarditis or other causes (23%). Before implantation, 23% had cardiac arrest, 38% were on a ventilator and 31% were on an intra-aortic balloon pump. Cardiac index was 1.6+/-0.5 L/min/m(2) and total bilirubin levels were 39+/-59 micromol/L. During support, 29 patients (35%) died in the intensive care unit and seven (10%) died after leaving. Forty-seven patients (56%) were weaned or transplanted, with one still under support. Despite significantly more advanced preoperative end-organ dysfunction, survival rates were similar in patients with biventricular devices (74%) and those undergoing isolated left ventricular support (24%) (63% versus 45%, respectively; p=0.2). Actuarial survival estimates after transplantation were 78.7+/-6.3%, 73.4+/-6.9% and 62.6+/-8.3% at 1, 3 and 5 years, respectively.
Conclusions:
Our experience validates the use of p-VAD as a primary device to support patients with cardiogenic shock. In contrast to short-term devices, p-VADs provide immediate ventricular unloading and pulsatile perfusion in a single procedure. Biventricular support should be used liberally in patients with end-organ dysfunction.
Related Concept Videos
Cardiomyopathy V: Interprofessional Care
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation (NIPPV)
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Cardiomyopathy II: Dilated Cardiomyopathy
Treatment for Pulmonary Arterial Hypertension: Oxygen Therapy for Respiratory Failure
Oxygen therapy is vital in increasing and maintaining blood oxygen levels in PAH patients. As a result, it aids in reducing fatigue, improving...
Cardiac Catheterization II: Right Heart Catheterization