Large coronal shear fractures of the capitellum and trochlea treated with headless compression screws
Mark Mighell1, Nazeem A Virani, Robert Shannon
1Division of Arthritis and Joint Reconstruction, Florida Orthopaedic Institute, Tampa, FL 33637, USA. mmighell@floridaortho.com
Background:
The purpose of this study is to retrospectively evaluate the clinical outcomes of 18 patients with large coronal shear fractures of the capitellum and lateral trochlea that underwent open reduction and internal fixation with headless compression screws.
Methods:
Eighteen patients were identified (16 women, 2 men) with an average age of 45 years and an average follow-up of 26 months. Fractures were classified according to the Dubberley classification as 11 type-1A injuries and 7 type-2A injuries.
Results:
All patients, with the exception of 1, had good to excellent functional results by the Broberg-Morrey scale (mean score, 93.3). Average arc of motion was 128 degrees in flexion/extension and 176 degrees in pronation/supination. Radiographically, 3 patients had subsequent development of avascular necrosis and 5 developed arthrosis. No significant negative correlation was noted between the development of avascular necrosis and clinical outcome. Minor complications occurred in 2 patients, but there were no re-operations.
Conclusion:
Headless compression screw fixation allows for stable fixation in patients with large coronal shear fractures of the distal humerus without posterior comminution.
Level Of Evidence:
4.
Related Concept Videos
Fractures: Bone Repair
Minor fractures with no bone displacement are treated by immobilizing the fractured bone using a cast or splint. However, in the case of fractures with displaced bones, the broken bones are repositioned before immobilization to ensure successful healing without deformation and loss of function. The realignment of fractured bone ends is performed through a process called reduction. If the procedure...
Sutures of the Skull
Sutures are immobile joints between adjacent bones of the skull. The narrow gap between the bones is filled with dense, fibrous connective tissue that unites the bones. The long sutures located between the skull bones are not straight but instead follow irregular, tightly twisting paths. These twisting lines tightly...