The trabecular bypass stent in a pseudophakic glaucoma patient: A 1-year follow-up
Antonio M Fea1, Monica Dogliani, Federica Machetta
1Istituto di Fisiopatologia Clinica, Clinica Oculistica, Università di Torino, Italy.
Purpose:
To describe the 1-year success of a trabecular stent implant in a pseudophakic glaucoma patient. The stent is implanted through a small corneal incision under gonioscopic control. Intraocular pressure control was reported in cultured human anterior segment.
Design:
Observational case report.
Methods:
We report the case of a patient who was implanted and followed-up for 1 year at the Dipartimento di Fisiopatologia Clinica. The main outcome measures were intraocular pressure and visual field.
Results:
The patient's intraocular pressure was controlled with topical beta-blockers for 6 months and without therapy for 6 months. Two diurnal curves demonstrated achievement of target pressure during the day. The 1-year visual field was unchanged.
Conclusions:
We are not aware of previous reports of trabecular stent implantation in pseudophakic patients. The trabecular stent had minimal peri-operative morbidity. Identification of the implantation site is challenging and reduction of efficacy over time may occur.