Related Experiment Video
Updated: Jun 21, 2026

Determining Basal Energy Expenditure and the Capacity of Thermogenic Adipocytes to Expend Energy in Obese Mice
Published on: November 11, 2021
[Intensive care patients. Determining daily energy expenditure - a comparison of two methods]
K Rokuss1, A Kalenka, H-J Bender
1Klinik für Anästhesiologie und Operative Intensivmedizin, Universitätsmedizin Mannheim, Mannheim.
Introduction:
Using indirect calorimetry (IC), required energy demand may be determined. The SenseWear (SW) armband uses skin temperature, galvanic skin response, heat flux, and a 2-axis accelerometer to estimate daily energy expenditure (EE). The aim of the present study was to evaluate accuracy of the SenseWear measurements in critically ill and ventilated patients.
Material And Methods:
After approval of the local ethics committee and written informed consent, critically ill and ventilated patients were enrolled. During a 24-h study period EE was continuously measured using the SW armband (standardized position at right upper arm); an IC was performed additionally. Measurement bias (DeltaEE) was calculated as DeltaEE=EE(SW)-EE(IC). Daily energy expenditure of both techniques (IC vs. SW) was compared using regression analysis and the Bland Altman method. The t-Test for paired samples was used for statistical analysis, p<0.05 was considered statistically significant.
Results And Discussion:
In total, 23 critically ill and ventilated patients (17 male, 6 female; means: 59.9+/-17.3 years; body mass index 28.0+/-6.3 kg/m(-2)) were investigated. A mean bias of DeltaEE=-565.65+/-1,748.07 kJ (-135.0+/-417.2 kcal) [range: -4,709.56+/-2,224.89 kJ (-1,124 to +531 kcal); p=0.3547] was calculated. Bland-Altman analysis revealed that SW slightly overestimates IC energy expenditure for critically ill patients in the hypo- and normocaloric range [<7,123 kJ/24 h: DeltaEE=+644.42+/-1,038.70 kJ (<1,700 kcal/24 h: DeltaEE=+153.8+/-247.9 kcal); p=0.0838], but significantly underestimated IC values in the hypercaloric range [>10,056 kJ/24 h: DeltaEE=-2,679.09+/-1,698.63 kJ (>2,400 kcal/24 h: DeltaEE=-639.4+/-405.4 kcal); p=0.0098].
Conclusions:
The SenseWear armband is non-invasive, convenient and easy to handle, but has a significant measurement bias in the hypercaloric range. Although IC is still best suited to determining metabolic need in intubated patients, measurements with the SenseWear armband provide significant advantages, e.g. in non-intubated patients, and give a fair estimation of daily energy expenditure when used alone.
Related Concept Videos
Energy Balance
Drug Dosing in Renal Diseases: Estimation of Glomerular Filtration Rate Based on Serum Creatinine Concentration
Metabolic Rate
The Basal Metabolic Rate (BMR) measures the energy expended at rest.
Several factors influence the...
