An analytical approach to estimating the first order scatter in heterogeneous medium. II. A practical application
Weiguang Yao1, Konrad W Leszczynski
1Department of Medical Physics, Sudbury Regional Hospital, 41 Ramsey Lake Road, Sudbury, Ontario P3E 5J1, Canada. wyao@hrsrh.on.ca
Abstract:
Recently, the authors proposed an analytical scheme to estimate the first order x-ray scatter by approximating the Klein-Nishina formula so that the first order scatter fluence is expressed as a function of the primary photon fluence on the detector. In this work, the authors apply the scheme to experimentally obtained 6 MV cone beam CT projections in which the primary photon fluence is the unknown of interest. With the assumption that the higher-order scatter fluence is either constant or proportional to the first order scatter fluence, an iterative approach is proposed to estimate both primary and scatter fluences from projections by utilizing their relationship. The iterative approach is evaluated by comparisons with experimentally measured scatter-primary ratios of a Catphan phantom and with Monte Carlo simulations of virtual phantoms. The convergence of the iterations is fast and the accuracy of scatter correction is high. For a sufficiently long cylindrical water phantom with 10 cm of radius, the relative error of estimated primary photon fluence was within +/- 2% and +/- 4% when the phantom was projected with 6 MV and 120 kVp x-ray imaging systems, respectively. In addition, the iterative approach for scatter estimation is applied to 6 MV x-ray projections of a QUASAR and anthropomorphic phantoms (head and pelvis). The scatter correction is demonstrated to significantly improve the accuracy of the reconstructed linear attenuation coefficient and the contrast of the projections and reconstructed volumetric images generated with a linac 6 MV beam.
Related Concept Videos
Methods of Medium Optimization
Estimation of the Physical Quantities
Model Approaches for Pharmacokinetic Data: Distributed Parameter Models
The distributed parameter models are specifically designed to account for variations and differences in some drug classes. This model is particularly useful for assessing regional concentrations of anticancer or...
Scatter Plot
Linear Approximations
Analysis Methods of Pharmacokinetic Data: Model and Model-Independent Approaches
The model approach uses mathematical models to describe changes in drug concentration over time. Pharmacokinetic models help characterize drug behavior in patients, predict drug concentration in the body fluids, calculate optimum dosage regimens, and evaluate the risk of toxicity. However, ensuring that the model fits the experimental data accurately...