The mouth-to-bag resuscitator during standard anaesthesia induction in apnoeic patients
Holger Herff1, Peter Paal, Thomas Mitterlechner
1Department of Anesthesiology and Critical Care Medicine, Innsbruck Medical University, Anichstrasse 35, 6020 Innsbruck, Austria. holger.herff@i-med.ac.at
Aim:
Ventilation of a non-intubated emergency patient by inexperienced rescuers with a standard bag-valve device may result in high inspiratory flow rates and subsequently high airway pressures with stomach inflation. Therefore, a self-inflating bag has been developed that requires lay rescuers to blow up a single-use balloon inside an adult bag-valve device, which, in turn, displaces air within the bag towards the patient. This concept has been compared to standard adult bag-valve devices earlier in bench models but not in patients.
Methods:
An anaesthetist who was blinded to all monitor tracings ventilated the lungs of 40 apnoeic patients during routine anaesthesia induction either with a standard bag-valve device or with the mouth-to-bag resuscitator in a random order. Study endpoints were peak inspiratory flow rates, peak airway pressure, tidal volumes and inspiratory time.
Results:
Peak inspiratory flow was 40+/-10lmin(-1) for the standard bag-valve device versus 33+/-13lmin(-1) for the mouth-to-bag resuscitator (P<0.0001); peak airway pressure was 17+/-5cmH(2)O versus 14+/-5cmH(2)O (P<0.0001); inspiratory tidal volume was 477+/-133ml versus 644+/-248ml (P<0.001) and inspiratory time was 1.1+/-0.3s versus 1.9+/-0.6s (P<0.0001).
Conclusion:
Employing the mouth-to-bag resuscitator during simulated ventilation of a non-intubated patient in respiratory arrest significantly decreased peak inspiratory flow and peak airway pressure and increased inspiratory tidal volume and inspiratory times compared to a standard bag-valve device.
Related Concept Videos
Cardiopulmonary Resuscitation II: ACLS Airway Management
Cardiopulmonary Resuscitation V: Advanced Airway Management Techniques
Administering Oxygen by Mask
Administering oxygen by mask is a common nursing intervention that provides supplemental oxygen to patients with respiratory distress or chronic lung conditions. This procedure involves delivering oxygen at a specified rate through a face mask connected to an oxygen source.
Equipment
The equipment necessary for this procedure includes:
Endotracheal Intubation I: Procedure
The ET tube comprises various components, including a standard adaptor to attach a bag-valve-mask (BVM) or ventilator, a cuff, a pilot balloon, and radiopaque markings along its length to measure the insertion distance. The tube sizes...
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...
Endotracheal Tube Extubation
Procedure
Extubation removes the endotracheal tube (ETT) from the patient on mechanical ventilation. It requires a well-coordinated, multidisciplinary approach involving physicians, nurses, respiratory therapists, and other healthcare professionals.