This study evaluated the effect of conventional versus ultrasonic cementation techniques on the fracture strength of resin composite laminates. In addition, the failure modes were assessed. Window-type preparations 1 mm above the cemento-enamel junction were made on intact human maxillary central incisors (N=60) of similar size with a depth cutting bur. All the prepared teeth were randomly assigned to six experimental groups (10/per group). Using a highly filled polymeric material (Estenia), laminates were produced and finished. The standard thickness of laminates in original tooth form was achieved using the impression molds made prior to tooth preparation. A three-step bonding procedure and dual polymerized resin composite cement (Panavia F 2.0) was employed. The cementation surfaces of the laminates were conditioned (CoJet-Sand, 30 microm SiO2) and silanized (ESPE-Sil). Laminates in Groups 1, 2, 3, 4 and 5 were cemented by five different operators under finger pressure and Group 6 was cemented ultrasonically (Amdent). After excess removal, the laminates were light polymerized. The specimens were stored in water at 37 degrees C for one month prior to the fracture test (universal testing machine, 1 mm/minute). Failure types were classified as: a) Cohesive failure within the composite laminate (Type A), b) Adhesive failure between the tooth and laminate (Type B) and c) Chipping of the laminate with enamel exposure (Type C). No significant difference was found among the mean fracture strength values of the laminates in all the experimental groups (ANOVA, p=0.251). The mean fracture strength values in descending order were: 513 +/- 197, 439 +/- 125, 423 +/- 163, 411 +/- 126, 390 +/- 94, 352 +/- 117 N for Groups 2, 5, 4, 3, 1 and 6, respectively. The majority of failure types was Type A (30/60). While Type B failure was not observed in Group 6 (0/10), Group 1 presented a more frequent incidence of this failure (6/10). The two cementation techniques did not effect the fracture strength of composite laminates, but failure types varied between groups, being more favorable for the ultrasonically cemented group.
Related Concept Videos
Strength of Cement
For compressive strength tests, ASTM C 109-05 standards prescribe a cement-sand mix ratio of 1:2.75 and a water/cement ratio of 0.485 for making 2-inch cubes. These cubes are mixed, cast, and cured in saturated lime water at 23°C until testing. Flexural strength testing, outlined in ASTM C...
Microcracking in Concrete