Granulation formation following tracheal stenosis stenting: influence of stent position
Po-Jen Ko1, Chien-Ying Liu, Yi-Chen Wu
1Department of Surgery, Chang Gung Memorial Hospital, School of Medicine, Chang Gung University, Tao-Yuan, Taiwan.
Objectives/Hypothesis:
To determine whether stent-to-vocal fold distance influences morbidity following stent placement for tracheal stenosis.
Methods:
Fifty-five stent procedures (46 Montgomery T-tube [Boston Medical Products, Westborough, MA] and 9 Dumon stents [Novatech, Grasse, France]) were performed in 40 patients enrolled in this study.
Results:
The most common complication of stenting for tracheal stenosis was granulation (23 procedures, 41.82%). Of 43 procedures where the stent upper edge was located at or below the vocal folds, granulation occurred in 21 procedures (48.84%). Of 12 procedures where the stent edge was located above the vocal fold, granulation occurred in two procedures, or 16.67% (odds ratio = 4.773, P = .0458, chi(2) test). Among patients in whom the stent edge was located at or below the vocal folds, the granulation complication rate was higher in those with a stent-to-vocal fold distance of <10 mm. Multivariate analysis revealed that the stent-to-vocal fold distance independently predicted granulation formation; an inverse correlation was identified between stent-to-vocal fold distance and granulation severity (n = 43, r = -.501, P = .0006; Spearman ranking test). Receiver operating characteristic curve analysis further demonstrated that a stent-to-vocal fold distance cutoff value between 9.5 and 11 mm had the best accuracy in predicting granulation formation.
Conclusions:
A stent-to-vocal fold distance of 10 mm was found to be a critical distance for discriminating granulation formation. Optimal stent-to-vocal fold distance should routinely be evaluated before stent placement.
Related Concept Videos
Tracheostomy Decannulation
Description of the Procedure
Decannulation refers to the permanent removal of the tracheostomy tube, signaling the resolution of the condition that initially necessitated the tracheostomy. The process requires a well-coordinated interplay between...
Tracheostomy: Procedure and Tubes
Tracheostomy tubes can be made of semiflexible plastic (polyurethane or silicone), rigid plastic, or metal, and they come in...
Trachea
Anatomical Features:
Location: About half of the trachea is situated in the neck, anterior to the esophagus, and extends from the larynx (at the level of the...
Tracheostomy Care I: Pre-procedural Steps
Required Equipment
The equipment necessary for tracheostomy care includes:
Mitral Stenosis I: Introduction
Oxygen Delivering System III: Tracheostomy and T-piece
Tracheostomy
A tracheostomy is a surgically created opening (stoma) in the anterior part of the trachea. It is used to establish a patient airway, bypass an upper airway obstruction, simplify the removal of secretions, permit long-term...