Dosimetric effects near implanted vascular access ports: an examination of external photon beam calculation
Michael S Gossman1, Jan P Seuntjens2, Monica F Serban3
1Tri-State Regional Cancer Center, Ashland, Kentucky, 41101, USA.
Abstract:
Vascular access ports are used widely in the administering of drugs for radiation oncology patients. Their dosimetric effect on radiation therapy delivery in photon beams has not been rigorously established. In this work the effects on external beam fields when any of a variety of vascular access ports is included in the path of a high energy beam are studied. This medical physics study specifically identifies side-scatter and back-scatter consequences as well as attenuation effects. The study was divided into two parts: Firstly, a total of 18 ports underwent extended HU range CT scanning followed by 3-D computer treatment planning, where independent homogeneity and heterogeneity plans were created for photon beams of energy 6 MV and 18 MV using a Pencil Beam Convolution (PBC) algorithm. Dose points were analyzed at locations all around each device. A total of 1,440 points were reviewed in this section of the study. Secondly, a mock-up of the largest vascular access port was created in the treatment planning workspace for further investigation with alternative treatment planning algorithms. Plans were generated identically to the above and compared to the results of dose computation between the Pencil Beam Convolution algorithm, the Analytical Anisotropic Algorithm (AAA), and the EGSnrc Monte Carlo algorithm with user code DOSRZnrc (MC). A total of 300 points were reviewed in this part of the study. It was conclusive that ports with more bulky construction and those with partial metal composition create the largest changes. Similar effects are seen for similar port configurations. Considerable differences between the PBC and AAA in comparison to MC are noted and discussed. By thorough examination of planning system results, the presented vascular access ports may now be ranked according to the greatest amount of change exhibited within a treatment planning system. Effects of backscatter, lateral scatter and attenuation are up to 5.0%, 3.4% and 16.8% for 6 MV and 7.0%, 7.7% and 7.2% for 18 MV respectively.
More Related Videos
06:20Irradiator Commissioning and Dosimetry for Assessment of LQ α and β Parameters, Radiation Dosing Schema, and in vivo Dose Deposition
Published on: March 11, 2021
07:31Characterization of Recombination Effects in a Liquid Ionization Chamber Used for the Dosimetry of a Radiosurgical Accelerator
Published on: May 9, 2014
Related Concept Videos
Biological Effects of Radiation
Radiation: Applications
The average...
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...