Determination of Photoreceptor Cell Spectral Sensitivity in an Insect Model from In Vivo Intracellular Recordings
Published on: February 26, 2016
Vacuum-ultraviolet spectral-irradiance calibrations: method and applications
W R Ott1, J M Bridges, J Z Klose
1National Bureau of Standards, Washington, DC 20234, USA.
Optics Letters
|August 21, 2009
Summary
This study introduces a new method for measuring spectral irradiance in the vacuum ultraviolet region. The technique achieves high accuracy, with uncertainties below 10% for various light sources.
Area of Science:
- Physics
- Optical Engineering
- Metrology
Background:
- Accurate spectral irradiance measurements are crucial for various scientific and industrial applications.
- Traditional methods for vacuum ultraviolet (VUV) spectral irradiance determination face challenges in precision and standardization.
Purpose of the Study:
- To present a novel method for determining spectral irradiance in the VUV range.
- To establish a reliable measurement technique using advanced spectral radiance standards.
Main Methods:
- The method utilizes recently developed spectral radiance standards for calibration.
- Measurements were performed in the wavelength range of 138 to 310 nm.
- Absolute spectral irradiance scales were established for different radiation sources.
Main Results:
- The developed method successfully determined spectral irradiance in the VUV spectrum.
- Spectral irradiances of multiple light sources were measured on an absolute scale.
- Estimated uncertainties for the measurements were less than 10%.
Conclusions:
- The new method provides a precise and accurate way to measure VUV spectral irradiance.
- The use of spectral radiance standards enhances the reliability of these measurements.
- This advancement supports improved characterization of radiation sources in the VUV region.
Related Concept Videos
Ultraviolet and Visible (UV–Vis) Spectroscopy: Overview
Ultraviolet–visible (UV–visible or UV–Vis) spectroscopy is an analytical technique that investigates the interaction between matter and UV–Vis light within the electromagnetic spectrum. This method is widely used for its versatility, simplicity, and relatively quick data acquisition, making it valuable for both qualitative and quantitative analysis. When UV–Vis radiation passes through a material, molecules absorb light depending on the energy required for electronic transitions. As a result...
UV–Vis Spectrometers
The absorbance of UV and visible (UV–visible) radiations is measured using a UV–visible spectrophotometer. Deuterium lamps, which emit UV radiation, and tungsten lamps, which produce radiation in the visible region, are used as light sources in UV–visible spectrophotometers. A monochromator or prism is used for diffraction grating, i.e., to split the incoming radiation into different wavelengths. A system of slits is used to focus the desired wavelength on the sample cell. Samples for...
Instrument Calibration
Instrument calibration is essential for ensuring that instruments produce accurate and consistent results. It is vital in manufacturing, healthcare, testing laboratories, and scientific research. Calibration processes are specific to each instrument and help enhance data accuracy. Each instrument has a unique calibration process tailored to its design and function to improve data accuracy.
Analytical Balance Calibration
An analytical balance measures mass and requires regular calibration to...
Analytical Balance Calibration
An analytical balance measures mass and requires regular calibration to...
UV–Vis Spectroscopy: Beer–Lambert Law
The Beer-Lambert law describes the relationship between absorbance and concentration, which combines the principles established by scientists Johann Heinrich Lambert and August Beer. Lambert's law states that when light passes through a medium, the loss in intensity is directly proportional to the original intensity and the path length of the light. Beer's law proposed that the transmittance of a solution remains constant if the product of concentration and path length is constant. The modern...
IR Spectrometers
There are two main infrared (IR) spectrophotometers: dispersive IR spectrometers and Fourier transform infrared (FTIR) spectrometers. In a dispersive IR spectrometer, a beam of infrared radiation produced by a hot wire is divided into two parallel equal-intensity beams using mirrors. One beam passes through the sample, while another is a reference beam. The beams then move through the monochromator, which separates the radiations into a continuous spectrum of different frequencies. The...
Atomic Emission Spectroscopy: Lab
AES is a powerful analytical technique, especially effective when used with plasma sources, producing abundant spectra in characteristic emission lines. The Inductively Coupled Plasma (ICP), in particular, yields superior quantitative analytical data due to its high stability, low noise, low background, and minimal interferences under optimal experimental conditions. However, newer air-operated microwave sources are emerging as promising alternatives that could be more cost-effective than...