Raman Spectroscopy Instrumentation: Overview
A conventional Raman spectrophotometer includes a laser source, a sample holding system, a wavelength selector, and a detector.
The monochromatic laser source, typically using visible or near-infrared radiation, generates a highly focused beam of light. This light interacts with the molecules of the sample, scattering some of the light. Liquid and gaseous samples are usually tested in ordinary glass capillaries, while solids can be analyzed as powders packed in capillaries or as potassium...
The monochromatic laser source, typically using visible or near-infrared radiation, generates a highly focused beam of light. This light interacts with the molecules of the sample, scattering some of the light. Liquid and gaseous samples are usually tested in ordinary glass capillaries, while solids can be analyzed as powders packed in capillaries or as potassium...
Raman Spectroscopy: Overview
The underlying principle of Raman spectroscopy is based on the interaction between light and matter, specifically molecules' inelastic scattering of photons. When a monochromatic beam of light, typically from a laser source, interacts with a sample, most scattered light has the same frequency as the incident light. This is known as Rayleigh scattering.
However, a small fraction of the scattered light exhibits a frequency shift due to the exchange of energy between the incident photons and the...
However, a small fraction of the scattered light exhibits a frequency shift due to the exchange of energy between the incident photons and the...
¹H NMR of Conformationally Flexible Molecules: Temporal Resolution
At room temperature, the chair conformer of cyclohexane undergoes rapid ring flipping between two equivalent chair conformers at a rate of approximately 105 times per second. These two chair conformers are in equilibrium. The rapid ring flipping results in the interconversion of the axial proton to an equatorial proton and an equatorial to the axial proton. Such interconversions are too rapid and cannot be detected on the NMR timescale. Hence, the NMR spectrometer cannot distinguish between the...
2D NMR: Homonuclear Correlation Spectroscopy (COSY)
Homonuclear correlation spectroscopy, or COSY, is a 2-dimensional NMR technique that provides information about coupled protons. Typically, the geminal and vicinal coupling are observed. For example, consider the COSY spectrum of ethyl acetate, where its 1D proton NMR spectrum is plotted along the vertical and horizontal axes with their corresponding chemical shift scale. Three spots on the diagonal corresponding to the three peaks in the 1D proton spectrum are called diagonal peaks. The COSY...
¹H NMR of Conformationally Flexible Molecules: Variable-Temperature NMR
The axial and equatorial protons in cyclohexane can be distinguished by performing a variable-temperature NMR experiment. In this process, except for one proton, the remaining eleven protons are replaced by deuterium. The deuterium substitution avoids the possible peak splitting caused by the spin-spin coupling between the adjacent protons. The remaining proton flips between the axial and equatorial positions.
Spectroscopy of Carboxylic Acid Derivatives
Infrared spectroscopy is primarily used to determine the types of bonds and functional groups. In carboxylic acid derivatives, a typical carbonyl bond absorption is observed around 1650–1850 cm−1. For esters, the absorption is recorded at around 1740 cm−1, while acid halides show the absorption at about 1800 cm−1. Another acid derivative, the acid anhydrides, exhibit two carbonyl absorption around 1760 cm−1 and 1820 cm−1, arising from the symmetrical and unsymmetrical carbonyl vibration.
In the...
In the...