Related Experiment Video
Updated: Jun 20, 2026

Retroductal Submandibular Gland Instillation and Localized Fractionated Irradiation in a Rat Model of Salivary Hypofunction
Published on: April 24, 2016
Effect of radiotherapy on the microleakage of adhesive systems
Bilinç Bulucu1, Aysun Avsar, Ebru Ozsezer Demiryürek
1Department of Operative Dentistry, Faculty of Dentistry, Ondokuz Mayis University, Samsun, Turkey. bbulucu@omu.edu.tr
Purpose:
The aim of this in vitro study was to evaluate the effect of radiotherapy on the microleakage of three adhesive systems: a one-step self-etching, a two-step self-etching, and an etch-and-rinse system.
Materials And Methods:
Box-shaped Class V cavity preparations were prepared on the buccal surfaces of 84 extracted human molars. The molars were randomly assigned into 6 groups (n = 14) according to the irradiation and adhesive system as follows: G1, Clearfil S3 Bond (irradiated); G2, Clearfil SE Bond (irradiated); G3, Prime & Bond NT (irradiated); G4, Clearfil S3 Bond (nonirradiated); G5, Clearfil SE Bond (nonirradiated); and G6, Prime & Bond NT (nonirradiated). The cavities were restored with composite resin (Filtek Z 250). After restoration of the samples, a total dose of 60 Gy was delivered in 2 Gy/d fractions for 5 days per week for 6 weeks for the related groups. All specimens were thermocycled for 200 cycles between 5 degrees C and 55 degrees C using a dwell time of 60 s in each bath and then placed in 0.5% basic fuchsin solution for 24 h at room temperature. Specimens were then rinsed and sectioned; the dye penetration at the enamel and dentin margins was examined using a stereomicroscope, and a score of 0 to 3 was assigned. Data were analyzed using the Kruskal-Wallis and Mann-Whitney U-tests.
Results:
No statistically significant difference existed between the irradiated and nonirradiated groups (p > 0.05). Significant differences in microleakage were observed between enamel and dentin (p < 0.01). The microleakage at the dentin margins was greater than at the enamel margins. Prime & Bond NT revealed statistically significantly (p < 0.05) higher leakage scores in dentin than did ClearfilS3 Bond and Clearfil SE Bond.
Conclusion:
Within the limitations of this study, irradiation application did not affect the microleakage of dental adhesive systems.