Field performance of seven passive sampling devices for monitoring of hydrophobic substances
Ian J Allan1, Kees Booij, Albrecht Paschke
1Norwegian Institute for Water Research, Gaustadalléen 21, NO-0349 Oslo, Norway. ian.allan@niva.no
Abstract:
The performance of seven passive sampling devices for the monitoring of dissolved concentrations of polycyclic aromatic hydrocarbons (PAHs), polychlorinated biphenyls (PCBs), hexachlorobenzene, and p,p'-DDE was evaluated through simultaneous field exposures of 7-28 days in the River Meuse (The Netherlands). Data from the Chemcatcher, low density polyethylene membranes, two versions of the membrane-enclosed sorptive coating (MESCO) sampler, silicone rods, silicone strips and semipermeable membrane devices (SPMD) was assessed through rate of dissipation of performance reference compounds (PRCs), mass of analyte absorbed by the samplers and time-weighted average concentration (C(TWA)) data. Consistent PRC data throughout the range of samplers tested here confirmed the transition from membrane- to boundary layer-controlled exchange at log K(ow) 4.5-5.0. The comparison of sampler surface area-normalized masses absorbed for analytes under boundary layer-control showed some variability between samplers that can be attributed to the conformation and deployment of the various samplers and to the uncertainty associated with the analysis conducted in different laboratories. Despite different modes of calculation, relatively consistent C(TWA) were obtained for the different samplers. The observed variability is likely to be due to the uncertainty of sampler-water partition coefficients and the extrapolation of analyte uptake rates at the high log K(ow) range (under boundary layer-controlled exchange) from a narrow PRC data range, and these issues require further work. Finally, the usefulness of passive sampler-generated contaminant concentrations is demonstrated through the comparison with institutional monitoring and with European Water Framework Directive Environmental Quality Standards (EQS).
More Related Videos
09:04Identifying Per- and Polyfluorinated Chemical Species with a Combined Targeted and Non-Targeted-Screening High-Resolution Mass Spectrometry Workflow
Published on: April 18, 2019
12:50Continuous Instream Monitoring of Nutrients and Sediment in Agricultural Watersheds
Published on: September 26, 2017
Related Concept Videos
Sampling Methods: Sample Types
Solid samples include a variety of substances, such as sediments from water bodies, soil, metals, and biological tissues. Two standard methods for extracting sediments from water bodies are grab sampling and piston coring. Grab sampling involves using a device to collect a discrete sediment sample from the bottom of a water body with minimal disturbance. Grab samples do not always represent the entire area due to...
High-Performance Liquid Chromatography: Types of Detectors