Related Experiment Video
Updated: Aug 4, 2026

09:46
Construction and Evaluation of a Murine Calvarial Osteolysis Model by Exposure to CoCrMo Particles in Aseptic Loosening
Published on: February 17, 2018
Polyethylene liner cementation technique in asymptomatic versus symptomatic osteolysis
Leonid Kandel1, Gurion Rivkin, Adi Friedman
1Department of Orthopedic Surgery, Hadassah Medical Center, Hadassah Mount Scopus, Jerusalem, Israel.
Orthopedics
|August 28, 2009
Summary
Early treatment of asymptomatic osteolysis in cementless acetabular components is recommended. This intervention, involving polyethylene liner revision, can improve hip function and pain scores, though dislocation remains a concern.
Area of Science:
- Orthopedic Surgery
- Biomaterials Science
- Bone Biology
Background:
- Osteolysis, or bone loss, around cementless acetabular components is a significant complication in hip arthroplasty.
- This bone loss can compromise implant stability and lead to severe structural damage.
Purpose of the Study:
- To investigate the efficacy of early intervention for asymptomatic osteolysis in cementless acetabular components.
- To evaluate the outcomes of polyethylene liner revision in patients with varying degrees of osteolysis.
Main Methods:
- A retrospective study involving 34 patients (37 revisions) undergoing polyethylene liner revision for cementless acetabular component osteolysis.
- Patient-reported outcomes were assessed using the Harris Hip Score (HHS), with a mean follow-up of 5 years.
Main Results:
- Average HHS was 87, with a pain score of 39.
- Asymptomatic patients demonstrated significantly higher HHS (95) and pain scores (43) compared to symptomatic patients (P<.01).
- One patient experienced acetabular fracture due to extensive bone loss.
Conclusions:
- Revision of the polyethylene liner and cementation is a viable technique for managing osteolysis in patients with a stable acetabular shell.
- Early intervention in asymptomatic patients with osteolysis is advisable to improve functional outcomes.
- A high rate of dislocation is a notable concern following this revision procedure.